Miller ADI 253 Instruction Manual page 24

Table of Contents

Advertisement

4.5
Troubleshooting
Trouble
Remedy
No weld
output;
unit
completely
inoperative.
Place line disconnect switch
in
On
position (see
Section
2.9).
Check
and
replace
line
fuse(s),
if necessary,
or
reset
circuit breaker
(see
Section
2.9).
Check for proper
input
power connections
(see
Section
2.9).
No weld
output;
meter
display
On.
If
using
remote
control,
be
sure
process switch is in
a
position
that
provides
output
control
at
Remote
14
receptacle (see
Section
3.1
as
applicable).
Input voltage
outside
acceptable
range of variation
(see
Section
2.8).
Check,
repair,
or
replace
remote
control.
Unit overheated. Allow unit
to
cool with fan On
(see
Section
2.2).
Erratic
or
improper
weld
output.
Use proper size and
type
of weld cable
(see
Section
2.5).
Clean and
tighten
all
weld connections.
No 115 volts
ac
output
at
duplex
receptacle.
Reset circuit breaker CB1
(see
Section
4.2).
No 24 volts
ac
output
at Remote 14
receptacle.
Reset circuit breaker CB2
(see
Section
4.2).
.
20
OM-221 7

Advertisement

Table of Contents
loading

Table of Contents