Viking F-1 Installation Instructions Manual page 41

Class i; class ii; class iii; class iv gate operator
Table of Contents

Advertisement

LCD Display References
Meaning
LCD MSG
Multi Meter Displays
MOT AMP
This is the motor current amperage during operation
__._ A
MOT VOLT
This is the actual motor voltage during operation
__._ VDC
AC VOLT
This is the actual low voltage AC to the Control Board from the transformer
__._ VAC
CHARGE
Indicates the charging voltage to the batteries, if the Battery Switch is in
the OFF position.
__._ VDC
BAT VOLT
Indicates battery voltage, if the AC power is discontinued to the Control
Board.
__._ VDC
Board Settings Messages
EPS2
Indicates that the Electronic Positioning Sensor (EPS) needs to be tuned.
Error rate is displayed as a percentage
___% ERR
Speed
Shows the percentage of speed set by the Speed adjustment on the control
board. (pg 24)
__%
OVERLAP
Shows the number of seconds set by the Overlap Adjustment on the
control board.
_._ SEC
ODS SENS
Shows the force setting selected to trip the obstruction sensor. (pg 26)
___%
TIMER
Shows the amount time set or remaining to hold the gate at the Open Limit
position, before the gate starts to close. (pg 24)
__ SEC
HEATER
The Integrated Heater is disabled for the open
limits (pg 27)
__ OFF
HEATER
The Integrated Heater has been enabled to turn on at the open
__ ON
or close
VIKING TECHNICAL SUPPORT 1.800.908.0884
"CLS"
"*"
limits (pg 27)
TROUBLESHOOTING
"OPN"
and/or close
will be displayed while it is heating
Page 41
TS Ref #s
"CLS"
"OPN"
and/
3 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Class iClass iiClass iiiClass iv

Table of Contents