Astria Envy35TEN Installation And Operating Instruction Manual

Astria Envy35TEN Installation And Operating Instruction Manual

Direct-vent
Table of Contents

Advertisement

P/N 900005-00 Rev. B 10/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900005-01
P900005-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Envy
Models
PFS
Envy35TEN
®
C
US
EnvyCD35TEN
Report No. F14-105
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Direct-Vent Gas Fireplaces
Envy40TEN
EnvyCD40TEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Envy45TEN
EnvyCD45TEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Envy35TEN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Envy35TEN

  • Page 1 Installation and Operation Instructions Envy Direct-Vent Gas Fireplaces ™ P/N 900005-00 Rev. B 10/2015 Models Ce manuel est disponible en francais, simplement Envy35TEN Envy40TEN Envy45TEN ® en faire la demande. Numéro de la pièce 900005-01 EnvyCD35TEN EnvyCD40TEN EnvyCD45TEN Report No. F14-105 P900005-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: General Information

    Innovative Hearth Products General Information Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Astria™ Signature Series Envy Direct-Vent Gas Fireplaces 900005-00, 10/2015 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Traditional Fireplace Contemporary Fireplace THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 IMPORTANT SAFETY INFORMATION Important Safety Information Información importante de L’information de sûreté seguridad importante 1. WARNING: Do not operate appliance with the glass front removed, cracked 1. AVERTISSEMENT. Ne pas utiliser l’appareil si 1.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 For use with barrier(s) Part No(s). J7407 (35” Models), J7408 (40” Models), and J7409 (45” Models). Follow installation instructions. Reinstall any barrier removed before operating the appliance. The barrier is designed to reduce the risk of burns from hot glass.
  • Page 8: Packaging

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (Installation and Operation Instructions (this manual), Safety Flyer, Glass and Barrier Flyer and Safety-in-Operation Warning Labels •...
  • Page 9 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Codes and Standards These fireplaces comply with National Safety Standards and are tested and listed by PFS Corporation (Report No.F14-105) to ANSI Z21.88 (in Canada, CSA-2.33), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters.
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 VENT TERMINATION CLEARANCES These instructions should be used and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Table 6 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 5 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed Closed...
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 7), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in Figure 5). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 5).
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Figure 5 - Combustible Side Clearances Figure 6 - Mantel Height At 14-1/2” in. (mm) Mantel Depth minimum side wall 28 (711) At 13-3/4” At 5-1/2” clearance, a side wall side wall combustible clearance, a...
  • Page 16: Installation Sequence

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 17 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Table 9 - Fireplace Framing Specifications Framing should Model be constructed 39-3/4” 45-1/4” 24” 46-3/4” Vent Framing— 35” 10-1/2 of 2x4 or larger 1010 mm 1149 mm 610 mm 1187 mm Top Vent with material 12”...
  • Page 18: Prepare The Fireplace Top Standoffs

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Prepare the Fireplace Top Standoffs 1. Bend each of the two (2) L-shaped standoff components, at the designated places, into a U-shape (Figure 8). 2. Align the closed end of each U-shaped standoff component with the left/right side of the top, front of the fireplace and the attachement holes in the top of the fireplace (Figure 8).
  • Page 19: Rough In The Electrical Supply, If Needed

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 • A pipe joint compound rated for gas should be used on the threaded joints. Ensure propane-resistant compounds are used in propane applications. Be very careful that the pipe compound does not get inside the pipe.
  • Page 20 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 If desired install lower front filler panel Unit is shipped from the factory with a filler shipped loose with the unit. This filler is not needed if the non combustible hearth material extends up 7/8”...
  • Page 21: Select A Horizontal Or Vertical Vent System

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 VENT SYSTEM PREPARATION Select a Horizontal or Vertical Vent System 1. With the fireplace secured in the framing, determine the vent route and identify the exterior termination location. 2. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Use only approved vent components (Page 8 and Page 44).
  • Page 22 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Table 13 - Vent Section Length Nominal Section Nominal Section Length Length (in.) (in.) Net Section Length 10.5 22.5 34.5 46.5 Net Section Length (in.) 10.5 22.5 34.5 46.5 (in.) Height of Vent Height of Vent Number of Vent Sections...
  • Page 23: Install The Vent System

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Install the Vent System Install the Vertical Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 24 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Vertical (Offset) Installation 1. Analyze the vent route—Determine the number of vent sections (Table 13) and elbows (Figure 38) required. 2. Frame the ceiling opening—Use a plumb line from the ceiling above the fireplace to locate the center of the vertical run.
  • Page 25 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 8. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 40 for more information. 9.
  • Page 26 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 27 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 28 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 10. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run. Install support straps every 5 ft. (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape (Figure 21). Maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane.
  • Page 29 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Figure 22 - Installing the Horizontal Termination Firestop/Spacer (SV4.5HF) shown Typical Termination on the exterior side of the wall. It Shown may also be installed on the interior side. 10-1/2” 7”...
  • Page 30 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Horizontal Vent Figures/Tables NOTE: Secure Vent rigid vent pipe and terminal are shown in the figures. Secure Flex flexible vent pipe and ® ® terminal may also be used. NOTE: Two (2) 45° elbows may be used in place of one (1) 90° elbow. The same rise to run ratios, as shown in the venting figures for 90°...
  • Page 31 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Table 19 - Top Vent—Two 90° Elbows H + H Maximum V Minimum Wall firestop/spacer Wall Firestop/Spacer SV4.5HF ** (SV4.5HF) feet meters feet meters 0.91 0.490 1.58 0.914 2.07 1.22 2.56 1.524 Wall firestop/...
  • Page 32 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Vertical or Horizontal Venting Using Secure Flex Kits and Components Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent (SV4.5) ® direct-vent components can be used.
  • Page 33: Complete The Field Wiring

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4” from the end of the flexible vent. f. Install three (3) screws 120° apart through the flexible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection.
  • Page 34: Install And Initializing The Remote Control System

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Figure 26 - Wiring Diagram—Electronic Gas Valves Figure 27 - Wiring Diagram—Junction Box IPI Pilot Green Ground - Green Flame Sensor White Neutral - White Schematic Representation Only Spark Electrode 120 VAC - Black Black (Power...
  • Page 35 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Initialize the remote control system After completing fireplace installation, initialize the remote control system before operating the fireplace. 1. Insert the three (3) provided AAA batteries into the battery bay in the transmitter. Correctly align polarity (+/–). 2.
  • Page 36: Connect The Gas Line

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Connect the Gas Line All codes require a shutoff valve mounted in the supply line. The shutoff valve should be oriented to face the fireplace front. The flex-line method is acceptable in the U.S.A. where local codes permit it. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.
  • Page 37: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Test Factory and Field Connections for Gas Leaks WARNING Never use an open flame to check for leaks. 1. Turn ON the gas supply and test for gas leaks, using a gas leak test solution—also known as bubble leak solution. NOTE: Using a soapy water solution is an effective leak test solution but it is not recommended, because the soap residue that is left on the pipes/fittings can result in corrosion over time.
  • Page 38 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 CAUTION • Soot will be produced if the air shutter is closed too much. Any damage due to sooting, resulting from improperly setting the air shutter, is not covered under the warranty. •...
  • Page 39 Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 1. Remove the top louver and the surround trim assembly (Page 41). 2. Locate the air shutter adjustment rod in the lower control compartment (Figure 33), and adjust it to the standard setting.
  • Page 40: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Install the Vent Restrictor (if necessary) A vent restrictor may be needed with this appliance. The restrictor is installed in the appliance top flue outlet, either before adding vent from above, or after installation of vent from below—within the firebox. The restrictor is self securing with a positive friction fit.
  • Page 41: Install The Finishing Materials

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Install the Finishing Materials 1. Complete finished interior wall. NOTE: To install the fireplace facing flush with the finished wall, position framework to accommodate the thickness of the finished wall. 2.
  • Page 42: Attach The Safety-In-Operation Warning Labels

    Innovative Hearth Products Installation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 NOTE: The integrated finish trim is adjustable to accommodate a wall thickness of an additional 1” (25 mm)—for a 2” (51 mm) total thickness. NOTE: For wall thicknesses greater than 2” (51 mm), remove the three integrated finish trim pieces (Figure 40). Figure 41 - Non-combustible Wall Figure 42 - Wall Finishing Combustible...
  • Page 43 Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto—Nº de cat. H8024 Cat. No. H8024 Replacement Label Kit Astria.us.com Astria.us.com Astria.us.com Remarque : Le texte anglais est rouge sur un support Nota: La etiqueta en inglés es transparente con texto NOTE: English is red text on clear label.
  • Page 44: Installation Accessories

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 INSTALLATION ACCESSORIES Table 24 - Listed Secure Vent™ Components Catalog Catalog Models Description Models Description Number Number Horizontal square termination Chase top shroud kit, arch top, 3 H1968 SV4.5HT-2 with firestop / spacer (H2246) H1988 CTSA-33 x 3 ft...
  • Page 45: Gas Conversion Kits

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 46 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 47 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Figure 44 - Pilot Figure 45 - Orifice Pilot Orifice 12. Use pipe joint compound or Teflon tape on all pipe fittings before installing. ® NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds on flare fittings.
  • Page 48: Operation

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 49 étiquettes supplémentaires. gratuitas. INNOVATIVE HEARTH PRODUCTS Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024 Astria.us.com INNOVATIVE HEARTH PRODUCTS INNOVATIVE HEARTH PRODUCTS Astria.us.com Astria.us.com Note: English is red text on clear label. French and Spanish are white text on black label.
  • Page 50 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 51: Remote Control System

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Remote Control System WARNING Fire hazard. Can cause severe injury or death. The receiver causes ignition of the appliance. The appliance can turn on suddenly. Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system.
  • Page 52 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Turn ON the appliance 1. Press the ON/OFF key on the transmitter. 2. The transmitter display will show all active Icons on the screen. At the same time, the receiver will connect the thermopile to the gas valve millivolt coil and the appliance main burner will turn on.
  • Page 53: Firebox Liners

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Manual bypass of the remote control system If the batteries of the wall switch or transmitter are low or depleted, the appliance can be turned on manually. 1. Set the three-position slider switch to the ON position. 2.
  • Page 54: Installing The Logs

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Installing the logs WARNING • Turn OFF all gas and electricity to the appliance before installing the logs. • Do NOT install the logs until the appliance has been competely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 55 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 NOTE: Do not cover the burner ports. 1. If necessary, remove the glass door (Page 57). 2. Place Log 1 on the burner as shown (Figure 52). Figure 52 - Placing Log 1 Figure 53 - Placing Log 2 3.
  • Page 56: Installing And Removing The Glass Door

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 57 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 58: Maintenance

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 MAINTENANCE Refer to the Maintenance Schedule on Page 61 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 59 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Cleaning the glass door CAUTION Do not use abrasive cleaners on glass. Never clean the glass when it is hot. Clean the glass during the Burn-in Period, and then only when necessary and when the fireplace is cool. Wipe the surface with a clean, dampened, soft cloth.
  • Page 60 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Inspecting the wiring Refer to the wiring diagram (Figure 26, Page 34). CAUTION When servicing controls, label all wires prior to disconnection. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. ATTENTION Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher.
  • Page 61 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 30 - Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and Qualified Service Technician Inspect valve and ensure it is properly...
  • Page 62: Accessory Components

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 ACCESSORY COMPONENTS Santa Fe Firebox Liner Kits (Traditional) Choose from ceramic brick or porcelain panels. Andiron Kit (Traditional) Firebox Liner Kits For use with Envy™ Traditional fireplaces only. Cat. No. Model Description 35”...
  • Page 63: Lighting Instructions

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 LIGHTING INSTRUCTIONS - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. •...
  • Page 64 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 LIGHTING INSTRUCTIONS - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 65: Troubleshooting

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 66: Replacement Parts

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 REPLACEMENT PARTS Description Catalog Number Catalog Number Catalog Number Electronic Pilot Assembly, Natural Gas H7268 H7268 H7268 Flex Hose Connector, 24” H8997 H8997 H8997 Flex Hose Connector, 12” H8979 H8979 H8979 Flex Hose, 10”...
  • Page 67 Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Figure 59 - Replacement Parts Remote Table 33 - Homeowner Replacement Parts Description Catalog Number Catalog Number Catalog Number Surround Trim Assembly H8734 H8713 H8735 Glass Door H9017 H9018 H9019 Literature Kit H9020 H9020...
  • Page 68: Barrier Identification And Replacement

    Innovative Hearth Products Operation Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 REPLACING A DAMAGED BARRIER • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. • For use with barrier(s) Part No(s). J7407 (35” Models), J7408 (40”...
  • Page 69: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 70 Envy™ Direct-Vent Gas Fireplaces 900005-00, 10/2015 Contact an IHP dealer to obtain any of these parts. Please contact IHP for the phone number of your nearest IHP dealer. Astria.us.com Record the following important information about your fireplace: Fireplace model number...

This manual is also suitable for:

Envycd40tenEnvy45tenEnvycd45teEnvycd35tenEnvy40ten

Table of Contents