Wacker Neuson GV 6600A Operator's Manual
Hide thumbs Also See for GV 6600A:

Advertisement

Quick Links

www.wackergroup.com
OPERATOR'S MANUAL
0
1
7
0
8
1
4
E
N
0170814en
0108
Generator
GV 6600A
003

Advertisement

Table of Contents
loading

Summary of Contents for Wacker Neuson GV 6600A

  • Page 1 0170814en 0108 Generator GV 6600A OPERATOR’S MANUAL...
  • Page 2: Carbon Monoxide

    DANGER CARBON MONOXIDE Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide (CO). This is a poison you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even if you cannot smell the exhaust, you could be breathing CO.
  • Page 3: Table Of Contents

    GV 6600A Table of Contents Foreword Safety Information Laws Pertaining to Spark Arresters ............6 Operating Safety .................. 7 Operator Safety while using Internal Combustion Engines ....9 Service Safety ..................10 Label Locations .................. 11 Safety and Operating Labels .............. 12 Operation Determining Power Requirements .............
  • Page 4 Table of Contents GV 6600A Maintenance Engine Maintenance ................26 Periodic Maintenance Schedule ............26 Engine Oil ....................27 Servicing Air Cleaner ................28 Spark Plug ...................29 Cleaning the Sediment Cup ..............30 Storage ....................31 Transport .....................32 Troubleshooting ...................33 Technical Data Generator ....................34 Engine ....................35 Electrical Schematic ................36...
  • Page 5 CALIFORNIA Proposition 65 Warning: Engine exhaust, some of its constituents, and certain vehicle components, contain or emit chemicals known to the State of WARNING California to cause cancer and birth defects or other reproductive harm. Foreword This manual provides information and procedures to safely operate and maintain this Wacker model.
  • Page 6: Safety Information

    Safety Information GV 6600A Safety Information This manual contains DANGER, WARNING, CAUTION, NOTICE and NOTE callouts which must be followed to reduce the possibility of personal injury, damage to the equipment, or improper service. This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
  • Page 7: Operating Safety

    GV 6600A Safety Information Operating Safety Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use this generator inside a home or garage, EVEN IF doors and windows are open.
  • Page 8 Safety Information GV 6600A 2.2.7 NEVER operate the machine in snow, rain, or standing water. 2.2.8 NEVER allow untrained personnel to operate or service the generator. The generator set should be set up by a trained electrician. 2.2.9 NEVER stand on the machine.
  • Page 9: Operator Safety While Using Internal Combustion Engines

    GV 6600A Safety Information Operator Safety while using Internal Combustion Engines Internal combustion engines present special hazards during operation and fueling. Read and follow the warning instructions in the engine owner’s manual and the safety guidelines below. Failure to follow the DANGER warnings and safety guidelines could result in severe injury or death.
  • Page 10: Service Safety

    Safety Information GV 6600A Service Safety Poorly maintained equipment can become a safety hazard! In order for the equipment to operate safely and properly over a long period of time, periodic maintenance and occasional repairs are necessary. If WARNING the generator is experiencing problems or is being serviced, attach a “DO NOT START”...
  • Page 11: Label Locations

    GV 6600A Safety Information Label Locations wc_si000209gb.fm...
  • Page 12: Safety And Operating Labels

    Safety Information GV 6600A Safety and Operating Labels Wacker machines use international pictorial labels where needed. These labels are described below: Label Meaning DANGER! No sparks, flames or burning objects near machine. Shut off the engine before refueling. WARNING! Hot surface! Improper connection of generator to a building’s electrical system can allow electrical...
  • Page 13 GV 6600A Safety Information Label Meaning Open the fuel flow valve. Close the choke. Turn the engine switch to the ON position. Pull the rewind starter. Open the choke. Open main circuit breaker. Turn the engine switch to “OFF”. Close the fuel flow valve.
  • Page 14 Safety Information GV 6600A Label Meaning Electrical ground Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open.
  • Page 15: Operation

    GV 6600A Operation Operation Determining Power Requirements This generator is designed to operate single-phase, 60 Hz appliances running at 120 VAC. Check the nameplate or label provided on tools and appliances to make sure their power requirements match the power output of the generator.
  • Page 16: Installation

    Operation GV 6600A Installation Place the generator in an area where it will not be exposed to rain, snow, or direct sunlight. Make sure it is positioned on firm, level ground, so it will not slide or shift. Position the engine exhaust away from areas where people may be present.
  • Page 17: Generator Derating

    GV 6600A Operation Generator Derating All generators are subject to derating for altitude and temperature. Internal combustion engines, unless modified, run less efficiently at higher altitudes due to the reduction of air pressure. This translates into a lack of power and thus reduction in generator output.
  • Page 18: Grounding The Generator

    Operation GV 6600A Grounding the Generator A ground connection (a) is located on the generator frame. For proper operating safety, this ground terminal must be connected to a good ground source. This ground connection must comply with National Electrical Code standards, and state and local regulations.
  • Page 19: Use Of Extension Cords

    GV 6600A Operation Use of Extension Cords When a long extension cord is used to connect an appliance or tool to the generator, a voltage loss occurs—the longer the cord, the greater the voltage loss. This results in less voltage being supplied to the appliance or tool and increases the amount of current draw or reduces performance.
  • Page 20: Control Panel

    Operation GV 6600A Control Panel Ref. Description Ref. Description Engine switch GFI duplex receptacle—125V Auto idle switch GFI test button Twist-lock receptacle—125/250V GFI reset button Main circuit breaker Twist-lock receptacle—125V Voltage Selector Switch (VSS) wc_tx000709gb.fm...
  • Page 21: Ground Fault Interrupt (Gfi)

    GV 6600A Operation Ground Fault Interrupt (GFI) See Graphic: wc_gr003960 Each of the 125V, 20 Amp receptacles (f) is equipped with a ground fault circuit interrupt (GFI). The GFI shuts off power to the receptacle when a ground fault occurs to a piece of equipment attached to the generator.
  • Page 22: Voltage Selection

    Operation GV 6600A 3.11 Voltage Selection See Graphic: wc_gr003960 The voltage selector switch (VSS) (e) switches the generator output between the single-voltage mode (120V) and the dual-voltage (120/ 240V) mode. In single-voltage mode, the full rated power of the generator is shared between the two 125V GFI duplex receptacles and the 125V twist-lock receptacle.
  • Page 23: Before Starting

    GV 6600A Operation 3.13 Before Starting 3.13.1 Read and understand the safety and operating labels and instructions at the beginning of this manual 3.13.2 Inspect the generator for any signs of damage which may affect operation or pose a safety hazard.
  • Page 24: To Start

    Operation GV 6600A 3.14 To Start Before starting, be sure you read and understand all the safety and operating instructions in this manual. 3.14.1 Disconnect all loads from the generator and place the main breaker in the "OFF" position (a2).
  • Page 25: To Stop

    GV 6600A Operation 3.15 To Stop 3.15.1 Turn off and disconnect all tools and appliances attached to the generator. 3.15.2 Place main circuit breaker in the "OFF" position (a2). 3.15.3 Turn the engine switch to "OFF" (b2). 3.15.4 Close fuel valve (d2).
  • Page 26: Maintenance

    Maintenance GV 6600A Maintenance Engine Maintenance The chart below lists basic machine and engine maintenance. Refer to engine manufacturer’s Operator’s Manual additional information on engine maintenance. Periodic Maintenance Schedule Daily After Every Every Every before first starting 20 hrs. hrs.
  • Page 27: Engine Oil

    GV 6600A Maintenance Engine Oil 4.3.1 Drain the oil while the engine is still warm. 4.3.2 Remove the oil filler plug (a) and the drain plug (b) to drain the oil. Note: In the interests of environmental protection, place a plastic sheet and a container under the machine to collect any liquid that drains off.
  • Page 28: Servicing Air Cleaner

    Maintenance GV 6600A Servicing Air Cleaner Service the air cleaner frequently to prevent carburetor malfunction. NOTICE: NEVER run the engine without the air cleaner. Severe engine damage will occur. NEVER use gasoline or other types of low flash-point solvents for cleaning the air cleaner.
  • Page 29: Spark Plug

    GV 6600A Maintenance Spark Plug Clean or replace the spark plug as needed to ensure proper operation. Refer to the engine owner’s manual. The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Do not touch the muffler while it is hot.
  • Page 30: Cleaning The Sediment Cup

    Maintenance GV 6600A Cleaning the Sediment Cup 4.6.1 Turn the fuel valve off. 4.6.2 Remove the sediment cup (a) and the O-ring (b). 4.6.3 Wash both thoroughly in a nonflammable solvent. Dry and reinstall them. 4.6.4 Turn the fuel valve on and check for leaks.
  • Page 31: Storage

    GV 6600A Maintenance Storage Before storing the generator for a long period of time: 4.7.1 Close the fuel valve and remove and empty the sediment cup or fuel strainer. 4.7.2 Disconnect the fuel line from the carburetor. Place open end of fuel line into a suitable container and open fuel valve to drain fuel from tank.
  • Page 32: Transport

    Maintenance GV 6600A Transport Let the engine cool before transporting the generator or storing indoors, to avoid burns or fire hazards. WARNING When transporting the generator: 4.8.1 Turn the engine fuel valve to the OFF position. 4.8.2 Position the generator level to prevent fuel from spilling.
  • Page 33: Troubleshooting

    GV 6600A Maintenance Troubleshooting Problem / Symptom Reason / Remedy If engine doesn't start, check • Engine switch is on "Start". that: • Fuel valves under fuel tank and on engine are open. • Fuel tank has fuel. • Choke lever is in correct position. Choke should be closed when starting a cold engine.
  • Page 34: Technical Data

    Technical Data GV 6600A Technical Data Generator Item No. GV 6600A 0620289 Generator Maximum output 6600 Continuous output 6000 Type Single phase, self-exciting, 2-pole, field rotating AC voltages available Volts 120/240 phase Frequency Power factor cos ø AC receptacles: 125V GFI duplex (2)
  • Page 35: Engine

    GV 6600A Technical Data Engine Item No. GV 6600A 0620289 Engine Engine make Honda Engine model GX 390 K1 Operating power (max.) kW (Hp) 9.7 (13) Spark plug BPR6ES (NKG) Electrode gap mm (in.) 0.7–0.8 (0.028–0.031) Operating speed (max.) 3600...
  • Page 36: Electrical Schematic

    Technical Data GV 6600A Electrical Schematic wc_td000208gb.fm...
  • Page 37: Schematic Components

    GV 6600A Technical Data Schematic Components Ref. Description Ref. Description Ref. Description Generator Control Box Engine Ref. Description Ref. Description Main stator winding Spark plug Secondary winding Slip ring Rotor winding Auto idle unit Automatic voltage regulator Voltage selector switch Main circuit breaker Twist lock receptacle—125/250V...
  • Page 38 Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax: +49 - (0)89-3 54 02-3 90 Wacker Corporation · P.O. Box 9007 · Menomonee Falls, WI 53052-9007 · Tel. : (262) 255-0500 · Fax: (262) 255-0550 · Tel. : (800) 770-0957 Wacker Asia Pacific Operations ·...

This manual is also suitable for:

Gv 5600a

Table of Contents