Further details regarding the individual steps
Activating venting function with con-
stant temperature control unit:
1. Press OK and
simultaneously for
approx. 4 s.

Filling siphon with water

1. Pivot control unit forward.
2. Pull retaining clip A off.
3. Pull filler pipe B upwards.
Commissioning, inspection, maintenance
(cont.)
2. Select
"5" and confirm with OK.
When the venting function is activa-
ted, "EL on" is shown on the dis-
play.
3. Ending venting function:
Press
.
4. Pull off trap C downwards.
5. Fill siphon with water and reassem-
ble.
6. Refit cover panel.
27