Sleep Function Mode; Auto-Restart Function; Outdoor Chassis Heating Cable - Toyotomi MTN-MTG 256DV Service Manual

Table of Contents

Advertisement

9.15 Sleep function mode

9.15.1 Operation time in sleep mode is 7 hours. After 7 hours the machine quits this mode and turns off.
9.15.2 In cooling, heating or auto mode sleep function is available.
9.15.3 Operation process in sleep mode is as follow:
1) After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
2) When cooling, the setting temperature rises 1 (be lower than 30 ) every one hour, 2 hour later the
rising stops and indoor fan is fixed as low speed.
3) When heating, the setting temperature descends 1 (be lower than 30 ) every one hour, 2 hour later
the descending stops and indoor fan is fixed as low speed, and anti-cold-wind is available.
9.15.4 If user uses timer on function in sleep mode, sleep function will pause and not resume until reaches the setting
on time.
9.15.5 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the timing time is less
than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing time is more than 7
hours, the machine will not stop until reaches the setting off time in sleep mode.

9.16 Auto-Restart function

The indoor unit is equipped with auto-restart function. In case of a sudden power failure, the setting conditions
before the power failure will be restored. The unit will resume the previous operation setting automatically after 3
minutes when power returns.
9.17 Ionizer function (optional)
The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote controller
when the unit is turned on. Press the CLEAN AIR button to activate the function. Press it again to stop the function.
During the time when Ionizer being controlled by remote controller, Ionizer will be turned off automatically, if
indoor fan stops running due to malfunctions or anti-cold-wind. When indoor fan restarts after malfunctions
being eliminated and anti-cold-wind being released, Ionizer will be available again.
9.18 Outdoor heating cable (optional)
Outdoor chassis heating cable is fixed on outdoor chassis to help deicing and to avoid freezing. The chassis heating
cable's power is 85W, rated voltage is 220V-240V.
Outdoor crankcase heating cable is fixed around compressor to help starting compressor. The crankcase heating
cable's power is 20W, rated voltage is 220V-240V.
Outdoor heating cable will start to work when compressor stops and T4<3 .
Outdoor heating cable will stop working when T4>8 .