Communication Ports; Connection Of Rs232 Or Usb Communication Port (Optional); Installation Of The Communication Cards (Optional); Characteristics Of The Contact Communication Port (Optional) - Eaton Pulsar Series 650 Installation And User Manual

Pulsar series
Table of Contents

Advertisement

2.5 Communication ports

Connection of RS232 or USB communication port (optional)

The RS232 and USB communication ports cannot operate simultaneously.
4
6

Installation of the communication cards (optional)

230V/10A Max
Ue/In/Eing

Characteristics of the contact communication port (optional)

commun
n.o.
When a signal is activated, the contact is closed between the common (pin 4) and the pin for the corresponding
signal.
Contact characteristics (optocoupler)
Voltage: 48 V DC max
Current: 25 mA max
Power: 1.2 W
1
2
Us/Out/Ausg
I max 6.5A
1
Limited-access slot for the
communication card
1
5
4 3 2
1
4
9 8 7 6
n.o.
n.o.
1 - Connect the RS232 (20) or USB (21)
communication cable to the serial or USB
port on the computer equipment.
20
2 - Connect the other end of the
communication cable (20) or (21) to the
21
USB (6) or RS232 (4) communication port
on the UPS.
The UPS can now communicate with
EATON power management software.
It is not necessary to shutdown the UPS
before installing a communication card.
1 - Remove the slot cover (1) secured by
screws.
2 - Insert the communication card in the
slot.
3 - Secure the card cover with the two
screws.
n.o.: normally open contact
2. Installation
Pins 1, 2, 3, 5, 6: not used
Pin 4: common (user)
Pin 7: low battery
Pin 8: UPS ON, equipment supplied
Pin 9: operation on battery power
34008235EN/AC - Page 11