8.9. Field settings table

First
Second
code
code
Setting name
0
User permission level
00
User permission level
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (
03
Set point at high ambient temperature (Hi_Ti)
05
Weather dependent for cooling function
enable/disable
06
Low ambient temperature (Lo2_A)
07
High ambient temperature (Hi2_A)
08
Set point at low ambient temperature (Lo2_Ti)
09
Set point at high ambient temperature (Hi2_Ti)
2
Disinfection function
00
Operation interval
01
Status
02
Start time
03
Set point (for combination with domestic hot water
tank without built-in booster heater, [4-05]=5)
04
Interval (for combination with domestic hot water
tank without built-in booster heater, [4-05]=5)
3
Auto restart
00
Status
4
Backup heater operation and space heating off temperature
00
Backup heater operation
01
Not applicable. Do not change the default value.
02
Space heating off temperature
03
Booster heater operation
04
Not applicable. Do not change the default value.
05
Not applicable. Do not change the default value.
06
Backup heater emergency operation
07
Backup heater second step
5
Equilibrium temperature and space heating priority temperature
00
Equilibrium temperature status (for combination
with domestic hot water tank without built-in
booster heater, [4-05]=5, this setting is fixed and
can not be consulted)
01
Equilibrium temperature
02
Space heating priority status (for combination with
domestic hot water tank without built-in booster
heater, [4-05]=5, this setting is fixed and can not
be consulted)
03
Space heating priority temperature
04
Not applicable. Do not change the default value.
EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN
Daikin Altherma indoor unit
4PW64329-1 – 07.2010
Installer setting at variance with default value
Date
Value
Lo_Ti
)
Default
Date
Value
value
3
–10
15
40
25
0 (OFF)
20
35
22
18
Fri
1 (ON)
23:00
60
60
0 (ON)
1 (ON)
35
(a)
5
1
(enabled)
1
(enabled)
1 (ON)
0
1 (ON)
0
Range
Step
Unit
2/3
1
–20~5
1
°C
10~20
1
°C
25~55
1
°C
25~55
1
°C
0/1
10~25
1
°C
25~43
1
°C
5~22
1
°C
5~22
1
°C
Mon~Sun,
All
0/1
0:00~23:00
1:00
hour
fixed
5
°C
40~60
5
min
0/1
0/1/2
14~35
1
°C
fixed
0/1
1
0/1
1
–15~35
1
°C
–15~35
1
°C
Installation manual
35

Hide quick links:

Advertisement

Table of Contents
loading