Technical skilled person who is qualified to install products as per the subject of this manual. Before operating the unit, make sure the installation has been carried out correctly by a professional Daikin dealer. User: If you feel unsure about operation, contact your Daikin Person who is owner of the product and/or operates the product.
ENERAL SAFETY PRECAUTIONS pumps. These units are designed for floor standing indoor installation. The units can be combined with Daikin fan coil units, floor The precautions listed here are divided into the following four types. heating applications, low temperature radiators, Daikin domestic...
Schedule timer function The schedule timer function allows the user to schedule the operation of the installation according to a daily or a weekly program. Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
CLOCK DISPLAY The clock display shows the current time. When reading or programming the schedule timer, the clock display shows the action time. EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
It reverses the cycle and takes heat from the indoor system to prevent freezing of the outdoor system. After a maximum of 8 minutes of defrost operation, the system returns to the previous mode. Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
(space heating or space cooling). implies that the indoor heating and cooling capacity will also drop. Beware of this when a certain level of heating is required indoors. EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
If no button is pressed for 5 seconds, the controller leaves the mode" on page display mode. Switch the mode on or off at a scheduled time. Four actions can be programmed per mode. These actions are repeated daily. Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
"last" command settings are still active. The "next" programmed command will overrule the altered settings and return to the original program. EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
You automatically return to step 6. By pressing the pr button several times, you return to previous steps in this procedure and finally return to normal operation. 5 sec 5 sec Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
Select the day you would like to consult by means of the pi and pj buttons. The selected day is blinking. Press the < button to confirm the selected day. The first programmed action of the selected day appears. EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
After 5 seconds the display will show the next day (e.g. "2" if "1" was selected first). This indicates that the day has been copied. You can return to step by pressing the pr button. Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
LCD while the unit initialises itself. ■ Before shipping, the set values have been set as shown under "Field settings table" on page EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
(Hi_A). Note that the Hi_Ti value should be lower than Lo_Ti, as for warmer outdoor temperatures (i.e. Hi_A) less warm water suffices. Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
Page 15
Applies only to installations with a domestic hot water tank. required to disinfect the domestic hot water tank at a higher temperature (>60°C). In that case Daikin suggests to install The disinfection function disinfects the domestic hot water tank by a shunt pump and a heater element parallel on the periodically heating the domestic hot water to a specific temperature.
Page 16
■ [9-02] Cooling set point upper limit: maximum leaving water temperature for cooling operation. ■ [9-03] Cooling set point lower limit: minimum leaving water temperature for cooling operation. Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
Page 17
[C] Setup on EKRP1HB digital I/O PCB Solar priority mode ■ [C-00] Solar priority mode setting: for information concerning the EKSOLHW solar kit, refer to the installation manual of that kit. EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
°C Domestic hot water reheat set point hysteresis 2~20 °C Installation related settings Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting Operation manual EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
Page 19
Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting Installation related setting EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN Operation manual Daikin Altherma indoor unit 4PW64330-1 – 07.2010...
This maintenance should be carried out by your local Daikin technician (see installation manual). Do not try to dismantle the system yourself: the dismantling of the system, treatment of the refrigerant, of oil and other parts must be The only maintenance which may be required by the operator is: done by a qualified installer in accordance with relevant local and...