Self-Diagnosis Modes - Toshiba e-STUDIO203 Service Handbook

Hide thumbs Also See for e-STUDIO203:
Table of Contents

Advertisement

2.2

Self-diagnosis Modes

Mode
For start
Input check
[0]+[3]+
mode
[POWER]
Output check
[0]+[4]+
mode
[POWER]
Test print
[0]+[7]+
mode
[POWER]
Adjustment
[0]+[5]+
mode
[POWER]
Setting mode
[0]+[8]+
[POWER]
List print mode [9]+[START]
+[POWER]
Access code
[8]+[START]
mode
+[POWER]
Function set-
[1]+[*]+
ting mode
[POWER]
Note:
Note:
To enter the desired mode, turn ON the power while two digital keys designated to each mode
(e.g. [0] and [5]) are pressed simultaneously.
Normal
[0][3]
Input check
Output check
Warming up
mode
Ready
[POWER]
OFF
*1
To user
State transition diagram of self-diagnosis modes
*1 Turn OFF the power after using the self-diagnosis modes, and leave the equipment to the user.
December 2005 © TOSHIBA TEC
Contents
Checks the status of input signals.
Checks the status of output signals.
Outputs the test patterns.
Adjusts various items.
Sets various items.
Prints out the data lists of the codes 05/08 and
pixel counter.
Registers / deletes the access code.
Sets the function table.
[POWER]
ON
[0][4]
[0][7]
[0][5]
Test print
Adjustment
mode
mode
mode
Fig. 2-1
2 - 3
For exit
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[0][8]
[9][START]
Setting
List print
mode
mode
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
Display
[8][START]
[1][*]
Access code
Function
mode
setting mode
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio163

Table of Contents