3.10.2

Adjustment of ADF Height

Note:
Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the ADF.
[A] Checking
(1)
Close the ADF.
(2)
Light the exposure lamp.
Turn the power ON while pressing [0] and [4] simultaneously.
Key in [261], press the [START] button, and then wait until the CIS unit stops.
Key in [267] and then press the [START] button. The exposure lamp is turned ON for a given
length of time.
(3)
Visually check the gap between platen guide holder "A" and upper surface of the original glass
"B" from the left hand side of the equipment. If the value is not within the tolerance, perform the
adjustment according to the following procedure.
[Tolerance of the gap]
Rear side: 0 - 0.2 mm
Front side: 0 mm
e-STUDIO163/203 ADJUSTMENT
A
B
Fig. 3-50
3 - 50
A
B
December 2005 © TOSHIBA TEC