13)Black banding (at right angle with the feeding direction)
Defective area
Main charger
Fuser unit
High-voltage transformer
(Main charger / Developer
bias / Transfer charger)
Drum
Scanner
December 2005 © TOSHIBA TEC
Fig. 5-13
Step
Check items
1
Is the needle electrode dirty or
deformed?
2
Are the fuser roller, separation finger
for fuser roller and thermistor dirty?
3
Has the cleaning roller, pressure
roller, fuser roller and separation fin-
ger for fuser roller reached their PM
life?
4
Is the high-voltage transformer out-
put defective?
5
Is there a deep scratch on the drum
surface?
6
Is there thin scratch (drum pitting) on
the drum surface?
7
Are the original glass (especially the
position of shading correction plate)
and CIS unit dirty?
5 - 31
Prescription
Clean or replace the needle elec-
trode.
Clean them.
Replace them.
Adjust the output, or replace the
transformer.
Replace the drum if the scratch has
reached the aluminum base.
Check and adjust the contact condi-
tion of the cleaning blade and recov-
ery blade.
Clean them.
e-STUDIO163/203 TROUBLESHOOTING