Preparing Indoor Unit Installation; Remove The Intake Grille - Fujitsu SPLIT TYPE AIR CONDITIONER User Manual

Split type air conditioner
Hide thumbs Also See for SPLIT TYPE AIR CONDITIONER:
Table of Contents

Advertisement

INSTALLATION PROCEDURE
Install the room air conditioner as follows:

1. PREPARING INDOOR UNIT INSTALLATION

1. REMOVE THE INTAKE GRILLE

Open the intake grille and remove the three screws.
(Fig. 4)
Fig. 4
Screw
Intake grille
Remark : The main unit can be wired before
the indoor unit is installed. Select the
most appropriate installation order.
2. INDOOR UNIT INSTALLATION
A. FLOOR CONSOLE TYPE
1. DRILLING FOR PIPING
Select piping and drain directions. (Fig. 5)
The piping and drain can be made in three directions a
shown below.
Fig. 5
The drain hose can be connected to either the left or
right side. (Fig. 6)
Fig. 6
Drain hose (Left side)
When the directions are selected, drill a 4" (10cm) dia.
hole on the wall so that the hole is tilted downward
toward the outdoor for smooth water flow. When the
pipe is led out from the rear, make a hole in Fig. 7, at
the position shown.
Tapping screw
Drain hose (Right side)
Fig. 7
Wall
4" (100 mm)
Indoor side
Avoid areas where electrical wiring or
conduits are located.
Accidentally cutting a live wire can cause
death or injury.
When installing the set to wall, install the accessory
wall bracket at the position shown in Fig. 8, and
mount the set to it.
Fig. 8
39" (99 cm)
20" (50 cm)
2-1/2" (6.5 cm)
4" (10 cm) hole
2" (5 cm) hole
5" (12.5 cm)
2. INSTALLING DRAIN HOSE
INSTALL THE DRAIN HOSE
Select whether the drain hose will be connected to the
left or right side. (Fig. 6)
Insert the drain hose into drain pan, then secure the
drain hose with a nylon fastener. (Fig. 9)
Fig. 9
Drain pan
Drain hose
5
1/4" (6 mm)
Outdoor side
9-5/8"
Wall bracket
(24.5 cm)
Side of set
4" (10 cm)
Nylon fastener