Installing Brackets; Installing Indoor Unit; Outdoor Unit Installation; Install The Drain Hose - Fujitsu SPLIT TYPE AIR CONDITIONER User Manual

Split type air conditioner
Hide thumbs Also See for SPLIT TYPE AIR CONDITIONER:
Table of Contents

Advertisement

3. INSTALLING BRACKETS

Install the brackets with nuts, washers and spring
washers. (Fig. 18)
Fig. 18
Spring washer
Special nut
Bracket (Left)

4. INSTALLING INDOOR UNIT

Reset the hex bolts as shown in Fig.19.
Fig. 19
Indoor unit
Apply the indoor unit to the brackets.(Fig. 20)
Fig. 20
Bolt
Indoor unit
Now, securely tighten the hex bolts in both sides.

5. INSTALL THE DRAIN HOSE

Select whether the drain hose will be connected to the
left or right side. (Fig. 6)
Insert the drain hose into the drain pan, then secure
the drain hose with a nylon fastener. (Fig. 9)
Wrap the insulation (drain hose) around the drain
hose connection. (Fig. 10)
Be sure to arrange the drain hose so that it is leveled
lower than the drain hose connecting port to the
indoor unit. (Fig. 21)
Bracket
Bracket (Right)
Hex bolt
5/16" to 1/2"
(8 to 1 3mm)
Bracket
Fig. 21
Remove the hole cover.
Arrange the drain hose
lower than this portion.
OK
When drain hose is arranged backward. Secure the
drain hose with the VT wire. (Fig. 22)
Fig. 22
Piping hole
VT wire
hole
Pass the drain hose
Cut the grille
through here.

3. OUTDOOR UNIT INSTALLATION

• When the outdoor unit will be exposed to strong
wind, fasten it with bolts at the places indicated by
the arrows. (Fig. 23)
Fig. 23
Bottom
7
Drain hose
NO
Base (Bottom)
VT wire
Intake
grille
Drain hose

Hide quick links: