12. FRESH AIR INTAKE

• Open the hole and connect the duct. (Fig. 47)
Fig. 47
Rear side
13. MOUNT THE COVER PLATE AND
THE INTAKE GRILLE

1. MOUNT THE COVER PLATE (RIGHT)

(1) Cut a pipe exit hole in the right plate. This is only when
the pipe exits from the right side. (This operation is not
required when the protrusion is on the top or rear.)
Fig. 48
Cover plate(Right)
(2) Join the cover plates (right) and mount with screws.
(Fig. 49)
Fig. 49

2. MOUNT THE COVER PLATE (LEFT)

(1) Join the cover plates (left) and mount with screws.
Fig. 50
Cover plate (left)
Duct
3. MOUNT THE INTAKE GRILLE
(1) Cut the right side of the intake grille. This is only
when the pipe exits from the right side. (Fig. 51)
Fig. 51
(2) Insert the hinges on the bottom of the intake grille
into the holes in the base assembly. Then mount the
arms to the three areas on the top of the intake
grille. (Fig. 52)
Fig. 52