For example, assume the zone 1 is not ready. Typically this might mean that a
protected door or window Is open.
>>
Once the problems with each zone have been resolved the READY light
will appear and the system can be armed.
To ARM the system when the system is NOT READY one of the following actions
are necessary;
- Make the zone(s) ready. Determine which zones are not ready and perform what
is necessary to ready the zone(s) (example, close the door or window, etc.),or
- Bypass the zone(s) not ready. Bypassing should only be performed if the zone
cannot be made ready or intentionally will remain not ready. Remember, zones that
are bypassed are not protected when the system is armed.
6.
DISARMING
Disarming the security system will deactivate the burglary portions of the system.
This procedure can also be used to reset your system if you accidentally set off the
system ( example, opened a window while the system was armed, or excessive
amount of smoke activated fire protection system).
DISARM PROCEDURE:
[USER]
s '\
Enter your user code.
IF NO ALARMS HAVE TAKEN PLACE
Upon disarming the ARMING indicator will go off.
The system display will reflect the current status. LCD keypads should display the
SYSTEM READY display.
IF ALARMS HAVE TAKEN PLACE
if alarms or other conditions such as system troubles have taken place since the
initial system arming, they will appear on the display. The conditions that have occurred
appear in the zone display section of the keypad. LED based keypads will reflect the
current system status through the indicator lights as follows;
ALARM
Fast blinking.
BYPASS
Slow blinking low intensity.
TROUBLE
Slow pulse
NOT READY
Solid ON
Burglary alarms will be indicated with a STEADY sound through the keypad while
FIRE alarms will generate a pulsing sound.
LCD keypads will show the alarm conditions with a display as follows:
p!Ly
This display shows the zones in alarm. After entry of your four digit user code the
following display will appear:
r,,,,
if an intrusion has taken place while you were away, do not enter until the location
has been secured!!!.
>>
To clear the display of the alarm or trouble conditions and silence thl3
audible signal enter
[USER]
again.