SYSTEM TESTING
Thls control unit was manufactured under rigid quality standards. Maintenance is best
performed by your installing company with trained service personnel.
Installing Company:
Telephone Number:
It is recommended that you test your system once a week using the following
procedure:
Note: if your XL4612 system Is monitored by a Central Statlon then contact them prior
to performing this test.
l- Arm your security system.
2- Activate the system by opening a protected zone (example, window, or door).
3- Confirm that the alarm sounding device (bell or siren) activates. tt your system is
connected to a Central Station then the keypad will emit a ringback sound to confirm
that the signal was received.
4- Disarm the system to silence the system and return to normal status.
BATTERY TEST
In order to test the backup battery the following procedure should be performed;
l- Remove the AC transformer from the AC outlet by removing the restraining screw
which secures the transformer to the wall. (Note: the scTew Is not present in rodeIs
sold in Canada).
2. Observe that the AC light goes off on the keypad.
3- Activate your alarm system using steps 14 listed above.
4- Replace the AC transformer to the AC outlet and secure using the retaining saew
(Note: The retaining screw is not present in models sold in Canada).
The National Fire Protection Assodation publishes a standard for household fire
warning equipment. N.F.P.A. #74. Further information can be obtained by contacting;
NFPA Public Affairs Dept., Batterymarch Park, Quincy,MA 02269.
lf you have any further questions about the operation 01 your system, call your
installer.