Reset System - Quintum Tenor AF Product Manual

Voip switch
Table of Contents

Advertisement

Chapter 4: Diagnostics/Maintenance
PC's COM port
You are able to change the unit back to factory defaults, including the password, after initial config-
uration.
1. Click on Start> Programs> Accessories> Communications> HyperTerminal. The Connection
Description window is displayed.
2. Enter a connection name (i.e., name for the unit such as Tenor AF NJ). Click OK.
3. Choose the serial port on your PC from the Connect Using drop down list box (i.e., Direct to
COM 1). Click OK. The COM1 Properties window is displayed.
4. Select the following information:
Bits per Second: 38400
Data Bits: 8
Parity: None
Stop bits: 1
Flow control: None
5. Reset the unit. Information about the unit will scroll on the screen, followed by a message,
"WITHIN 4 SECONDS, PRESS 'r' FOR FACTORY DEFAULTS or 'i' to SET STATIC IP".
6. Type 'r'. A message asks you to confirm the factory default.
7. Type y. The configuration sets to factory defaults and the IP address related information will
remain unchanged. The login prompt is displayed. The default user name and password is
admin.

Reset System

The Reset system feature enables you to reset the system, including hardware and software. You can
reset through the Command Line Interface (CLI) as follows:
1. Access the CLI through a Telnet session. See the Command Line Interface (CLI) guide for more
information.
2. Access the Maintain-MasterChassis-1# prompt.
3. Type reset. You will be asked if you want to set the unit back to factory defaults.
4. Type yes to confirm (type no to cancel the restore). The system resets.
P/N 480-0084-00-12
VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
4-12