s e c t i o n 2
I N S T A L L A T I O N
The RoboScan Pro 518 package comes complete with the following items:
5 meters XLR-XLR cable
mains cable
mounting bracket and hardware
this user manual
Disconnect the fixture from AC power before proceeding.
I n s t a l l i n g a n d C h a n g i n g t h e L a m p
The RoboScan Pro 518 is designed to use the Osram HSD 250 and Philips MSD-250/2 dis-
charge lamps. Installing other lamps may damage the fixture. The lamp holder is pre-
adjusted at the factory. For precise alignment, see "Adjusting the Lamp" on page 13.
To minimize the risk of lamp explosion, replace the lamp before usage exceeds 2200 hours.
1.
Remove the 3 thumbscrews securing the lamp-socket assembly to the rear of
the RoboScan. Gently pull out the assembly.
2.
If replacing the lamp, remove the old lamp from the socket.
3.
Holding the new lamp in a clean cloth (do not touch the glass), carefully
insert it firmly and squarely into the lamp socket.
4.
If your fingers touch the glass, clean the bulb with a clean, lint-free cloth
wetted with denatured alcohol.
5.
Replace the lamp-socket assembly and tighten the thumbscrews.
C h e c k i n g Vo l t a g e a n d F r e q u e n c y S e t t i n g s
The voltage and frequency settings must match the local AC power supply! Operating at the
incorrect setting can result in poor light output, shortened lamp life, overheating and dam-
age to the fixture. The settings are printed on the serial number label on the front of the case.
If the voltage is not within 5 percent of the local supply, or if the frequency (50/60 Hz) is not
the same, then the ballast and/or transformer must be rewired as described on page 15.