Characteristic Data - Bosch 10P Installation & Operating Instructions Manual

Continuous flow gas water heater
Table of Contents

Advertisement

Characteristic Data

Pilot orifice diameter (mm)
Burner injector diameter (mm)
Burner pressure ( kPa )
Water flow selector at left hand stop.
Maximum water flow
Temperature rise
Minimum inlet pressure
Water flow selector at right hand stop
Minimum water flow
Temperature rise
Minimum inlet pressure
Refer to rating label located on the bottom right hand corner of the back panel for additional
data.
Weather
Freezing
In areas where the atmospheric temperature may drop below 0°C,
the heater must be drained to prevent damage by expansion of freezing
water. For appliances installed in locations where the temperature falls
below 0° C for brief periods , the installation of an EXOGEL expansion
valve, (part number H 707 060 151), will minimise the possibility of damage
to the appliance.
This water heater MUST NOT be installed in areas where the
temperature remains below 0°C for extended periods.
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas that for which it was
originally manufactured, please contact your local gas authority, authorised service agent or
the manufacturer
BISN0029
NG
0.30
LPG
0.19
TG
0.56
TLP
0.56
NG
1.20
LPG
0.75
TG
2.15
TLP
2.15
NG
0.87
4
LPG
2. 0
TG
0.40
TLP
0.40
10 litres / minute
25°C
NG
90 kPa
( 9.0 metres W.G.)
LP
55 kPa
( 5.5 metres W.G.)
4.5 litres / minute
55°C
NG
30 kPa
( 3 metres W.G. )
LP
10 kPa
( 1 metre W.G. )
Hot Water
Exogel
Page 3
25/10/2011
1 Metre
minimum

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents