• The control electronics must be coded when operated with
a load shedding relay. Remove the keying nose on the electronics
(4.).
• After anytime the unit is disconnected from power, e.g. at initial
operation, power failures, air bubble detected, 6 l/min of water have
to flow through appliance once. Only after this rinsing, the appliance
starts heating up. The reason for this behavior is to remove air
bubbles inside the heating element so a damage of the heating coils
can be avoided.
• The safety limiter (SL) disconnects all electrical components in the
event of a over-pressure or temperature. When the cause of the
actuation has been found / eliminated, the SL can be switched on
again by pressing the lock down button. Water pressure peaks in
3

Technical data

Rated output
Rated voltage
Fuse protection
Minimum conductor cross-section*
Warm water flow at rated output
with temperature increase from
12 °C to 38 °C (without flow-rate limiter)
12 °C to 38 °C (with flow-rate limiter)
12 °C to 60 °C
Start-up flow
Start-up flow pressure**
Application area in water
specific electric resistance at 15 °C
Rated pressure
Maximum permissible supply temperature
Maximum mains impedance at connection point
Energy efficiency class
Load profile
Annual energy consumption
Daily energy consumption
Sound power level
Hot water heating energy efficiency
Rated output
Rated voltage
Fuse protection
Minimum conductor cross-section*
Warm water flow at rated output
with temperature increase from
12 °C to 38 °C (without flow-rate limiter)
12 °C to 38 °C (with flow-rate limiter)
12 °C to 60 °C
Start-up flow
Start-up flow pressure**
Application area in water
specific electric resistance at 15 °C
Rated pressure
Tronic 4000 | 5000 | 6000 | 7000 – 6720876037 (2021/12)
installation due to flushing systems, pumping systems could trigger
the SL, so pressure regulation valves are advised at supply line in
order to minimize possible perturbations.
Risk of electric shock!
▶ This operation (Safety Limiter Reset) must be undertaken by a
qualified specialist company or official after sales service as such
operation is very dangerous and must only be done when appliance
is disconnected from mains supply.
[kW]
[V]
[A]
2
[mm
]
[l/min]
[l/min]
[l/min]
[l/min]
[MPa (bar)]
[Ωcm]
[MPa (bar)]
[°C]
[Ω]
[kWh]
[kWh]
[dB]
[%]
TR5000
11/13 EB
[kW]
11/13
[V]
400
[A]
25
2
[mm
]
2.5
[l/min]
6.0/7.1
[l/min]
5
[l/min]
3.3/3.8
[l/min]
2.5
0.04
[MPa (bar)]
0.4
[Ωcm]
≥ 1 300
[MPa (bar)]
1.0 (10)
WARNING
TR4000
TR4000
18 EB
21 EB
18
21
400
400
32
32
4
4
9.8
11.6
6.5
7.6
5.3
6.2
2.5
2.5
0.04
0.04
0.4
0.4
≥ 1 300
≥ 1 300
1.0 (10)
1.0 (10)
20
20
0.104
0.104
A
A
S
S
479
477
2,204
2,195
15
15
39
39
TR5000
TR5000R
15/18 EB
18/21 EB
15/18
18/21
400
400
32
32
4
4
8.1/9.8
9.8/11.6
6.5
7.6
4.4/5.3
5.3/6.2
2.5
2.5
0.04
0.04
0.4
0.4
≥ 1 300
≥ 1 300
1.0 (10)
1.0 (10)
Technical data
TR4000
TR4000
24 EB
27 EB
24
27
400
400
40
40
6
6
13
14.6
8.7
9.3
7.1
7.9
2.5
2.5
0.04
0.04
0.4
0.4
≥ 1 300
≥ 1 300
1.0 (10)
1.0 (10)
20
20
0.104
0.104
A
A
S
S
477
479
2,191
2,204
15
15
39
39
TR5000
TR5000
24/27 EB
21/24 EB
TR5000R
24/27 EB
21/24
24/27
400
400
40
40
6
6
11.6/13.0
13.0/14.6
8.7
9.3
6.2/7.1
7.1/7.9
2.5
2.5
0.04
0.04
0.4
0.4
≥ 1 300
≥ 1 300
1.0 (10)
1.0 (10)
11