Fault detection and management
The XSCF continuously monitors the status of the server for stable system operation,
and does the following if a fault is detected:
Prompt collection of fault information (hardware log)
Analysis of fault information
Identification of the faulty location
Hardware error and fault information are stored in XSCF. For information on the
error messages displayed and their explanations, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
The XSCF degrades the faulty components to continue system operation or resets the
system to prevent another problem from occurring.
Remote control and monitoring of the system
The XSCF provides the following functions to enable remote management of the
server:
Remote system monitoring through a LAN connection
Notification of fault information to the system administrator
Remote console input/output
2.6.3

Airflow Indicator

The airflow indicator indicates the amount of air emitted from the server while the
M3000 server is up and running. To display the value, use the showenvironment
air command.
CODE EXAMPLE 2-1
XSCF> showenvironment air
Air Flow:63CMH
The value does not include the peripheral devices.
Note – The showenvironment air command displays the calculated airflow
based on the fan speed such as Low speed (level -1) or High speed (level -7) etc. The
fan speed is displayed by the showenvironment Fan command.