TABLE 1-4
SPARC Enterprise M3000 Server Site Planning Guide.
TABLE 1-4
Item
Number of power cords
Redundancy
Input voltage
Rated current
Frequency
Power factor
* In a redundant configuration, the rated current per cable is half the value shown in
TABLE 1-4
† This value applies to the full configuration.
For information on how to replace the power supply unit, see the SPARC Enterprise
M3000 Server Service Manual.
1-18
SPARC Enterprise M3000 Server Overview Guide • March 2012
lists the electrical specifications. For the other specifications, see the
Electrical Specifications
Specifications
2 (one for each power supply unit)
1+1 redundant configuration
100 VAC to 120 VAC
200 VAC to 240 VAC
*
4.80 A/5.15 A (100 VAC to 120 VAC)
2.59 A/2.81 A (200 VAC to 240 VAC)
50 Hz/60 Hz
0.98 (100 VAC to 120 VAC, full configuration)
0.89 (200 VAC to 240 VAC, full configuration)
.