Heat & Glo SL-550BE Owner's Manual page 17

Table of Contents

Advertisement

1. Top Vent - Horizontal Termination - (continued)
Three Elbows
Note: There MUST be a 25% reduction
in total H when using fl ex vent except
when using the simple up and out
installation (see Figure 5.3).
Note: Use SL D- Series
components only.
WARNING
Fire Risk.
• When using SL-HRC-SS and SL-HRC-ZC-SS
termination caps on top vented fi replaces, a one
foot minimum vertical vent section is required
before installing fi rst elbow.
Figure 5.6
H
2
V
2
Heat & Glo • SL-550BE, SL-550BE-IPI • 2114-900 Rev. H • 2/08
V
Minimum
H
Maximum
1
1
90 Elbow Only
1-1/2 ft. 457 mm
1/2 ft.
152 mm 1-1/2 ft. 457 mm
1-1/2 ft. 457 mm
3 ft.
2-1/2 ft. 762 mm
5 ft.
3-1/2 ft.
1.1 m
7 ft.
4-1/2 ft.
1.4 m
14 ft.
H
+ H
MAX. =14 ft. (4.3 m)
1
2
V
+ V
+ H
+ H
MAX. = 40 ft. (12.2 m)
1
2
1
2
H
1
V
H
+ H
Maximum
1
2
2 ft.
610 mm
4 ft.
1.2 m
914 mm
6 ft.
1.8 m
1.5 m
10 ft.
3.0 m
2.1 m
14 ft.
4.3 m
4.3 m
14 ft.
4.3 m
1
17