1、How to choose an air conditioner:
a. Choice for reference: 150-170W/㎡ for average rooms;
b. Choice for reference: 160-200W/㎡ for small size offices;
c. Choice for reference: 220-350W/㎡ for restaurants;
d. Choice for reference: 200-300W/㎡ for entertaining venues;
e. Choice for reference: 220-280W/㎡ for the top floor.
Note:1W = 3.412btu.
2. Indoor Unit:
For indoor unit installation, the distance between its top and the ceiling shall
not be less than 10 cm -20 cm, and the distance from the ground should be between
2m to 2.6m. Also the wallboard must be smooth and straight, with its supporting force
of not less than 60 kg.
The location for installing the indoor unit shall be far away from heat source,
the space between it and the door or window should exceed 0.6m
3. Outdoor Unit:
The air conditioner outdoor unit should not occupy public sidewalks, the distance
between the mounting bracket installed along the road (on condition that the mounting
bracket does not affect the public access, it can be installed horizontally) and the
ground must exceed 2.5m. Also we shall remember that: a. the air flow must run freely.
b. we should protect famous ancient buildings during installation. c. the installation
does not affect the traffic.
The distance between air outlet of outdoor unit and the opposite object should
be more than 1 meter, otherwise the machine would stop running because of overload
by heat yield failure.
If the outdoor unit was opposite the resident's door or window, you should install
the machine as far as possible away from the adjacent doors windows and plants, and
the distance shall not be less than the following values: for the rated cooling
capacity not more than 4.5KW, the distance should be 3m.; for the rated cooling
capacity more than 4.5KW, the distance should be 4m.
It should remember to avoid installing at places where the natural environment
is harsh, such as heavy fumes and wind, direct sunlight or high-temperature and heat,
together with the place where children easily reach.
4. The Unit:
When installing the air conditioner, the outdoor unit should be below the indoor
unit so as to facilitate circle of refrigerant and refrigeration oil .(1)The height
difference between wall mounted indoor unit and the outdoor unit is generally not
more than 7 meters. (2)The connection pipe can't exceed 5 meters, and the longest
is 15 meters. When the length exceeds 5 meters, 20g fluoride is required to be added
for each exceeding 1m.