• Do not expose the device to directly squirting water. • Never insert any objects or limbs into the device. • Do not cover the device during operation. dehumidifier TTK 120 E / TTK 122 E...
Page 3
• The entire refrigerant circuit is a maintenance-free, storage. Do not drink it. Health hazard! hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air- conditioning or by Trotec. dehumidifier TTK 120 E / TTK 122 E...
Page 4
A corresponding repair manual is available from the Maintenance tasks which require the housing to be opened manufacturer upon request. must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. dehumidifier TTK 120 E / TTK 122 E...
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. dehumidifier TTK 120 E / TTK 122 E...
• with a cover to protect it from invasive dust, if necessary • Place no further devices or objects on top of the device to prevent it from being damaged. dehumidifier TTK 120 E / TTK 122 E...
• Only position the device in rooms where potentially leaking refrigerant cannot accumulate. • Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater). dehumidifier TTK 120 E / TTK 122 E...
On/Off button Switching the device on or off Timer button Switching the timer function on and off: 1 h to 24 h Plus button Increases the value for the desired room humidity level (adjustable from 30 % – 90 %) by 5 %. dehumidifier TTK 120 E / TTK 122 E...
Page 9
• Automatic switch-off upon expiry of a preset number of hours control panel (13). The function can be set in addition in all operating modes. The number of hours can be set in hourly increments (1 h to max. 24 h). dehumidifier TTK 120 E / TTK 122 E...
Page 10
The automatic defrost LED (16) is illuminated throughout the defrost process. The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket. dehumidifier TTK 120 E / TTK 122 E...
Trotec for repair. • Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely. dehumidifier TTK 120 E / TTK 122 E...
Page 12
The sensor for the Switch off the device and evaporation call the customer service. temperature is damaged. The room humidity The compressor stops and level is too low. the fan continues to run. dehumidifier TTK 120 E / TTK 122 E...
Page 14
Trotec. If required, visually inspect the filters for dirt. ü The device is switched off. ü The device is disconnected from the mains. dehumidifier TTK 120 E / TTK 122 E...
Page 15
7. Insert the cleaned or the new activated carbon filter. 8. Put the air filter back in. 4. Allow the filter to dry completely. Do not insert a wet filter into the device! dehumidifier TTK 120 E / TTK 122 E...
Page 16
If you do not intend to use the device for a considerable time: 2. Empty the condensation tank over a drain or sink. • Store the device according to the Transport and storage chapter. dehumidifier TTK 120 E / TTK 122 E...
Minimum distance to walls or other objects top (A): 50 cm 50 cm rear (B): 50 cm 50 cm sides (C): 50 cm 50 cm front (D): 50 cm 50 cm 25 kg 27 kg Weight dehumidifier TTK 120 E / TTK 122 E...
Page 19
Power PCB Power Cord Shell Motor Capacitor Tube Temp. Sensor Up Grille Isolate Plate Capillary Grille net Compressor Capacitor down grille Fan blade Magnetic Switch Solenoid valve assembly Motor Base Compressor Condenser Casters dehumidifier TTK 120 E / TTK 122 E...
Have the refrigerant (propane) disposed of appropriately and according to the national regulations by a company with the relevant certification (European Waste Catalogue 160504). dehumidifier TTK 120 E / TTK 122 E...