• Check accessories and connection parts for possible Information marked with this symbol indicates that the damage prior to every use of the device. Do not use any operating manual must be observed. defective devices or device parts. Operating manual – dehumidifier TTK 110 HEPA...
Page 3
Trotec. • Discharge the collected condensate before transport and storage. Do not drink it. Health hazard! Operating manual – dehumidifier TTK 110 HEPA...
The released ions remove pollen, dust, viruses and bacteria from the room air. Thanks to this air purification method, the quality of the room air can be additionally improved. Operating manual – dehumidifier TTK 110 HEPA...
Control panel prevent it from being damaged. Air inlet (behind cover) Condensation drain hose connection Air filter HEPA filter Condensation drain hose Condensation tank with filling level indicator Air outlet Transport handle Wheels Operating manual – dehumidifier TTK 110 HEPA...
• Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges. • Make sure that extension cables are completely unrolled. Operating manual – dehumidifier TTK 110 HEPA...
Air purification mode is active the HEPA filter is installed) indication (Only possible when HEPA filter is 30 Ionisation indication Air purification by ionisation is used) indicated (only possible when the HEPA filter is installed) Operating manual – dehumidifier TTK 110 HEPA...
Page 8
ð The desired room humidity is indicated in the display for the 1. Press the MODE button (23) until the indication for the current room humidity (14) for approx. 5 s. Then the current laundry drying function (15) appears on the display. relative room humidity is displayed again. Operating manual – dehumidifier TTK 110 HEPA...
Page 9
Night mode can be switched on in all operating modes. When the operating mode is changed, night mode remains active. In night mode, the device runs with a low fan speed. 1. Press the SLEEP button (24) to switch night mode on or off. Operating manual – dehumidifier TTK 110 HEPA...
Page 10
ð The characters OFF and the number of hours left until switch-off appear on the temperature and timer indication (18). ð The timer setting equals the desired number of hours. ð The device switches off after the set period of time. Operating manual – dehumidifier TTK 110 HEPA...
Page 11
Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation. Operating manual – dehumidifier TTK 110 HEPA...
Using insertion tools or accessories other than those chapter Maintenance). If the condenser is dirty, have it specified in the operating manual may cause a risk of cleaned by a specialist company or by Trotec. injury. • The device might carry out an automatic defrost. During...
Page 13
Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair. Operating manual – dehumidifier TTK 110 HEPA...
Replace the air filter Check the HEPA filter for dirt and foreign objects and clean or replace if necessary Replace the HEPA filter Check for damage Check the attachment screws Test run Operating manual – dehumidifier TTK 110 HEPA...
Page 16
ð The filter usage indication (25) is reset to 0. Refrigerant circuit • The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air- conditioning or by Trotec. Operating manual – dehumidifier TTK 110 HEPA...
Page 17
1. Remove the air filter from the device. 3. Allow the filter to dry completely. Do not insert a wet filter into the device! 4. Reinsert the air filter into the device. Operating manual – dehumidifier TTK 110 HEPA...
Page 18
2. Empty the condensation tank over a drain or sink. • Store the device according to the Storage chapter. 3. Rinse the tank with clear water. Clean the tank regularly using a mild cleaning agent (no detergent!). Operating manual – dehumidifier TTK 110 HEPA...
Further information is provided on the nameplate. other objects Dispose of the refrigerant appropriately and according to the A: top: 50 cm national regulations. B: rear: 30 cm C: side: 30 cm D: front: 30 cm Weight 18 kg Operating manual – dehumidifier TTK 110 HEPA...
Page 20
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...