Regs Chart

APPLIANCE LOCATION

(1)
This water heater is approved for outdoor installation only.
(2)
Do not install this water heater with any modification or alteration.
(3)
Do not install this water heater indoors or in an enclosed space .
WARNING:
FLUE OUTLET MUST BE FREE FROM ANY COMBUSTIBLE MATERIAL.
CLEARANCES FOR FLUE TERMINAL (front of heater)
The location of the flue terminal must comply with the clearances shown on this page. If you
are unsure about clearances not indicated here, in general refer to AG601, or your local
authority. In Western Australia refer to the SECWA rules and regulations.
Use as a guide only. Refer to AS5601 or local gas fitting rules
for specific locations
T = Flue Terminal
I = Mechanical air inlet
Ref
a
Below eaves, balconies and other projections
Appliances up to 50MJ/h input
Appliances over 50 MJ/h input
b
From the ground, above a balcony or other surface
c
From a return wall or external corner
d
From a gas meter
e
From an electricity meter or fuse box (P)
f
From a drain pipe or soil pipe
g
Horizontally from any building structure or obstruction facing a flue terminal
h
From any other flue terminal, cowl, or combustion air intake
j
Horizontally from an opening window, door, non-mechanical air inlet. Or other opening into
a building with the exception of sub floor ventilation
Appliances up to 150 MJ/h
Appliances over 150MJ/h input up to 200 MJ/h input
Appliances over 200 MJ/h input
All fan assisted flue appliances in the direction of discharge
k
From a mechanical air inlet, including spa blower
n
Vertically below an openable window, non-mechanical air inlet, or any other opening into a building
with the exception of sub-floor ventilation:
Space heaters up to 50 MJ/h
Other appliances up to 50 MJ/h
Appliances over 50 MJ/h and up to 150 MJ/h input
Appliances over 150 MJ/h input
M = Gas Meter
P = Electrical meter or fuse box
Item
Shaded area indicates
prohibited area
W = Window
Minimum
Clearance
mm
Natural
Fan
draft
assisted
300
200
500
300
300
300
500
300
1000
1000
500
500
150
75
500
500
500
300
500
300
1500
500
1500
1500
1500
1500
1000
150
150
500
500
1000
1000
1500
1500
10