Adding Engine Oil; Changing Engine Oil; Air Filter Maintenance - Wp2500 And Wp2800; Cleaning The Air Filter - Westinghouse WP2500 Owner's Manual

Hide thumbs Also See for WP2500:
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE

Adding Engine Oil

NOTICE
Oil crankcase capacity is 0.6 liter. Do not overfi ll.
1. Always operate or maintain the pressure washer on
a fl at surface.
2. Stop engine if running.
3. Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
4. Thoroughly clean around the oil fi ll plug/dipstick.
5. Remove oil fi ll plug/dipstick and wipe clean.
6. See Engine Oil Specifi cation on page 39 for the
proper engine oil.
7. Slowly add engine oil to the engine. Stop frequently
to check the level to avoid overfi lling.
8. Continue to add oil until the oil is at the correct
level. See Checking Engine Oil on page 39.

Changing Engine Oil

1. Stop the engine.
2. Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
3. Place oil pan (or suitable container) under one
of the two oil drain plugs. The oil drain plugs are
located on either side of the engine.
4. With a damp rag, thoroughly clean around the oil
drain plug.
5. Place a fl exible piece of plastic or cardboard below
the oil drain plug and above the frame.
6. Remove the oil drain plug (see Figure 55). Once
removed, place the oil drain plug on a clean
surface.
40
Figure 55 – Oil Drain Plug – WP3000Z
7. Remove the oil fi ll plug/dipstick so the oil can drain
more easily from the oil drain port.
8. Allow oil to completely drain.
9. Replace oil drain plug.
10. Fill crankcase with oil following the steps outlined in
Adding Engine Oil on page 40.
11. Dispose of used engine oil properly.
AIR FILTER MAINTENANCE –
WP2500 AND WP2800
!
WARNING
Never use gasoline or other fl ammable
solvents to clean the air fi lter. Use only
household detergent soap to clean the
air fi lter.

Cleaning the Air Filter

The air fi lter must be cleaned after every 50 hours of
use or 3 months (frequency should be increased if
pressure washer is operated in a dusty environment).
1. Turn off the pressure washer and let it cool for
several minutes if running.
2. Move the pressure washer to a fl at, level surface.
3. Push down on the air cleaner cover to disengage
the cover from the top tab (see Figure 56).

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Wp2800Wp3000z

Table of Contents