NAME
ioxadm - manage External I/O Expansion Units
SYNOPSIS
ioxadm [-f] [-p] [-v] [-M] env [-e] [-l] [-t] [ target [ sensors]]
ioxadm [-f] [-p] [-v] [-M] list [ target]
ioxadm [-f] [-p] [-v] [-M] locator [on|off] [ target]
ioxadm [-f] [-p] [-v] [-M] poweroff target
ioxadm [-f] [-p] [-v] [-M] poweron target
ioxadm [-f] [-p] [-v] [-M] reset target
ioxadm [-f] [-p] [-v] [-M] setled [ on|off|slow|fast] target led_type
ioxadm -h
DESCRIPTION
ioxadm(8) manages External I/O Expansion Units and link cards attached to the
system.
The ioxadm(8) command is not available on the M3000 server.
For this utility, an operand with parameters and a target device must both be
specified. The target device can be a downlink card mounted in a built-in PCI slot
in the host system; an External I/O Expansion Unit; or a field replaceable unit
(FRU) in an External I/O Expansion Unit. The downlink card is identified by a
string which identifies the host path to the card. An uplink card is an FRU in the
I/O boat.
You must have one of the following privileges to run these commands:
Privileges
Required Privileges
platop
platadm
fieldeng
Refer to setprivileges(8) for more information.
Operands
env, list
env, list, locator, poweroff, poweron
All operands
System Administration
ioxadm(8)