Winterizing; Troubleshooting - Speck pumps Badu EcoM3 Installation, Operating And Service Manual

Hide thumbs Also See for Badu EcoM3:
Table of Contents

Advertisement

Routine Maintenance - continued
6. Replace lid with locking ring. Hand-tighten the lid to make an air-tight seal. Do not use any tools to
tighten the lid.
7. Verify that all valves have been returned to the proper position for normal operation. Turn on the
power to the pump.

Winterizing

CAUTION: The pump must be protected when freezing temperatures are expected. Allowing the
pump to freeze will cause severe damage and void the warranty.
There are two options when winterizing the pump
Option 1:
1. Drain all the water from the pump, system equipment, and piping.
2. Remove drain plugs. Do not replace plugs. Store the plugs in the empty strainer basket for winter.
3. Keep the motor covered and dry.
Option 2:
1. Drain all the water from the pump, system equipment, and piping.
2. Remove the pump and motor from the plumbing and store indoors in a warm and dry location.
Note: When the winter season is over the pump will need to be primed prior to start. Refer to
Section 4 Operation, Start Up Guide.
CAUTION: DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged
and the pump will start to leak. If this occurs, the mechanical seal will need to be replaced. ALWAYS
maintain the proper water level in your pool. Continued operation in this manner could cause a
loss of pressure, resulting in damage to the pump casing, impeller, and mechanical seal.
6

Troubleshooting

WARNING: The pump must serviced by a professional service technician qualified in pool/spa
installation. The following procedures must be followed exactly. Improper installation and/or
operation can create dangerous electrical hazards, which can cause high voltage to run through
the electrical system. This can cause property damage, serious personal injury, and/or death.
Improper installation and/or operation will void the warranty.
The Badu EcoM3 warnings are indicated by a flashing LED light on the control panel. If the error light is
on pay attention to the appropriate number of flash intervals of short or long duration, then shut the pump
down immediately. For example, if a "Low Voltage" warning occurs, the LED will blink two times, then off,
then blink two times. This sequence is repeated until the condition is cleared.