9.4 Adding a wired sensor to the Door/Window Sensor DS18
The DS18 Door/Window Sensor has an input or contact for an extra wired sensor. These sensors need to be of
type NC (normally closed contacts). There should not be any power on this contact (potential-free).
A few examples:
Securing a window with multiple magnetic contacts.
•
Adding extra sensors to your system, e.g. smoke detectors, temperature sensors, sensors to detect
•
electrical failures, etc.
1. Open the transmitter part of the DS18 by taking the two parts apart.
2. Remove the wire bridge from the connection for the wired sensor (2).
3. Connect the wired sensor.
The wired contact has its own Zone on the Base Console. You can register the contact using the procedure in
4.1.3 (to register a sensor, activate the alarm with your sensor in step 5).
9.5 Emergency sensors (always mode)
Your system also gives you the option to turn any sensor registered with the system into a so-called emergency
sensor. An emergency sensor will also activate the security system when the system is not switched on. When
an emergency sensor triggers an alarm, you will hear 'Alarm cause by emergency sensor' before the spoken
message you recorded. A few examples:
A panic button connected to the wired input on the console.
•
A door or window that should not be opened at any time.
•
A temperature or level sensor that warns you when a certain value or level is exceeded.
•
Setting a sensor to always mode:
1. To access the menu, press the menu UP? or menu DOWN button. The display now shows ENTER PIN.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The display is cleared
and shows a * for each number entered.
3. When the PIN code has been entered correctly, the word INSTALL will show up on the display.
4. Use the menu buttons UP/DOWN? to go to menu item 7. OPTIONS . Press OK to select this menu item. You can
also go to this menu item directly by pressing a 7 on the number pad.
5. Use the menu buttons UP/DOWN ? t o go to menu item SENSOR MODE . Press OK to select this menu item.
6. The display now reads SET ALWAYS SENSORS . You can see on your display (top and bottom) which zones and
sensors have been registered.
7. If you want to turn zone 31 into an emergency sensor, enter 31 on the number pad and press OK. Zone
number 31 will start flashing.
8. If you also want to turn zone 5 into an emergency sensor, enter 5 on the number pad and press OK. Zone
number 5 will start flashing.
9. If you want to turn zone 31 into a normal sensor again, enter 31 on the number pad and press OK. Zone 31 will
stop flashing.
10. Press CLEAR again to quit the menu.
? M ake sure the DS18 Door/Window Sensor is set to MIN if you want the message to be passed on without a
delay (see 8.1). Same applies for Motion Sensors on zone 15 and/or 16.
9.6 Sensor 27-32 ON/OFF
Used for setting zone 27 to 32 sensors to send Home Automation ON or OFF commands on House Code +1
and Unit Code 7-12, in respond to alarm triggers from sensors registered to respective zones 27-32 (e.g. zone
27 is related to UC 7, 29 to 9 etc). At present in this mode (menu options ) you see the installed sensors in zones
27-32 only as numbers round the side of the display, just like for setting sensor mode. When entering the Sensor
Zone number followed by ON or OFF the respective Zone number around the edge flashes to indicate it has
been set to send a X10 Home Automation command which is either ON or OFF depending on the choice made.
9.7 Deregistering a Door/Window or Motion Sensor
1. To access the menu, press the menu UP or menu DOWN ? b utton. The display now shows ENTER PIN .
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The display is cleared
and shows a * for each number entered.
3. When the PIN code has been entered correctly, the word INSTALL will show up on the display.
4. Press OK.
5. Enter the number of the zone you want to erase on the number pad and press CLEAR.
6. You are asked to confirm CLEAR ZONE 1. YES 2. NO.
7. Press 1 to erase the zone. The zone number is shown on the display.
8. Press CLEAR again to quit the menu.
Zones 31 and 32 can not be erased.
9.8 Power Failure Alarm: When the system is in armed mode, and there may occur a mains power failure
which lasts for at least 15 minutes, the console will dial out and give a message "POWER FAILURE"