If you have more than 2 remote controls installed, it will show e.g. RMOT 3 SET, RMOT 4 SET, ... RMOT 16 SET . You can
register up to 16 remote controls.
6. Repeat step 5 for every remote control you wish to register.
7. Press CLEAR to go back to the first menu item. . Press CLEAR again to quit the menu. To confirm your
choice, press 1 for Yes or 2 for No. If you choose Yes, you will quit the menu. If you choose No, you go back to
the first menu item. .
4. Installing the sensors
4.1 Door/Window Sensor DS18
3
4
5
6
8
1. Transmitter part – Built-in antenna.
2. Control indicator LED – When pressing the Tamper contact button, or when the unit is transmitting a signal
to the base station, this LED will light up. When the LED blinks weakly, batteries have to be replaced.
3. Magnet contact – The distance between magnet and contact may not be more than 5mm. When mounted,
make sure the small arrows on the magnet and transmitter base part are lined up.
4. Screw holes for mounting the sensor.
5. Switch for entry delays – For setting a delay time of approximately 30 seconds.
6. Tamper contact.
7. Battery compartment.
8. Connection for extra wired contact.
4.1.1 Mounting the Door/Window Sensor DS18
1.) Open the casing by taking the two pieces apart. Mount the
transmitter part on the frame of your door or window. Do not close
the casing yet.
2.) Mount the magnet on the moving part of your door of window.
Make sure that the arrows on the transmitter part (see the arrow!)
and the magnet are facing each other when the door or window is
closed. Keep the distance between the transmitter part and the
magnet (when door or window is closed) as small as possible (max.
5 mm).
Door/Window Sensors may be hidden behind drapes for a
more discreet installation.
If your window or doorframe is slightly countersunk, you can also place the
transmitter part and the magnet at a 90-degree angle. Once you have decided
on a definite place for the sensor, we advise to also fix the magnet with screws
(included).
Aluminium/synthetic frames
Place the sensor as high as possible: This gives the best range. Mark the place
for the transmitter and the magnet. Do not place the magnet directly on a metal
surface. In case of metal frames, or synthetic frames with a metal core, place a
piece of wood or plastic (min. 5mm thick) between the magnet and the frame.
On metal frames the space between the sensor and the magnet should be no
more than 3mm when the window or door is closed.
Sliding windows
In case of sliding windows the sensor and magnet should NOT be allowed to slide along each other. Place the sensor and magnet
in such a way that when closing the window the magnet and sensor approach each other like in the picture on the right side.
1
2
7
Need help?
Do you have a question about the PROTECTOR+ and is the answer not in the manual?