8 – Language Dictionary
TRIGger:SEQuence2:LEVel:VOLTage
TRIGger:ACQuire:LEVel:VOLTage
This command sets the trigger level for internally triggered voltage measurements. A positive voltage
trigger occurs when the voltage level changes from a value less than the lower hysteresis band limit to a
value greater than the upper hysteresis band limit. Similarly, a negative voltage trigger occurs when the
voltage level changes from a value greater than the upper hysteresis band limit to a value less than the
lower hysteresis band limit.
Command Syntax TRIGger:SEQuence2:LEVel:VOLTage<NRf+>
Parameters 0 to MAX (see table 8-3)
*RST Value 0
Examples TRIG:SEQ2:LEV:VOLT 5
Query Syntax TRIGger:SEQuence2:LEVel:VOLTage?
Returned Parameters <NR3>
Related Commands TRIG:SEQ2:LEV:CURR
TRIGger:SEQuence2:SLOPe:CURRent
TRIGger:ACQuire:SLOPe:CURRent
This command sets the slope of an internally triggered current measurement.
POSitive
triggering occurs on the rising edge.
triggering occurs on the falling edge.
NEGative
triggering occurs on either edge.
EITHer
Command Syntax TRIGger:SEQuence2:SLOPe:CURRent<slope>
Parameters EITHer | POSitive | NEGative
*RST Value POSitive
Examples TRIG:SEQ2:SLOP:CURR POS
Query Syntax TRIGger:SEQuence2:SLOPe:CURRent?
Returned Parameters <CRD>
Related Commands TRIG:SEQ2:SLOP:VOLT
132
TRIGger:ACQuire:LEVel:VOLTage<NRf+>
Unit V (volts)
TRIG:ACQ:LEV:VOLT MAX
TRIGger:ACQuire:LEVel:VOLTage?
TRIGger:ACQuire:SLOPe:CURRent<slope>
TRIGger:ACQuire:SLOPe:CURRent?
TRIG:SEQ2:HYST:VOLT
TRIG:ACQ:SLOP:CURR EITH