2-4-4.

Checking that Unpacking is Complete

!
Caution
If all packing materials are not removed from the IMAGER as instructed on the preceding pages,
the IMAGER will be damaged when power is applied.
1. Check that you have removed from the back of the IMAGER:
2 PLASTIC TUBES from the bottom of the PLATEN AY (see page 2-12)
TAPE and FOAM from the top of the PLATEN AY (see page 2-12)
One CABLE TIE and TAG from the TRANSLATION MOTOR (see page 2-12)
2 CABLE TIES and TAGS from the FILM PICKUP AY (see page 2-12 )
2. Check that you have removed from the front of the IMAGER:
2 SCREWS and TAGS from the PLATEN AY (see page 2-14)
RUBBER STRIP from the slot in the OPTICS MODULE (see page 2-15)
PLASTIC BAG from the CHARCOAL FILTER (see page 2-16)
3. Close the FRONT DOOR.
4. Discard the packing materials.
2-5.

Connecting to Electrical Power and the Network

2-5-1.

Electrical Power Setup

1. Use a VOLTMETER to measure the AC voltage at the wall outlet that will be used by the IMAGER.
2. From the bag of 5 VOLTAGE SELECTION PLUGS supplied in the ACCESSORIES PACKAGE, select
the PLUG that matches the measured wall voltage:
For Measured Voltage of:
90 -- 105 V AC
106 -- 130 V AC
180 -- 210 V AC
211 -- 230 V AC
231 -- 250 V AC
2005 July Rev. B
7F3318
Select PLUG with:
Brown Wires
Red Wires
Orange Wires
Yellow wires
Blue Wires
Section 2 - - Installation
2-17