Health - Cisco Small Business 200 Series Administration Manual

Small business 200 series smart switch
Hide thumbs Also See for Small Business 200 Series:
Table of Contents

Advertisement

Administration

Health

Clearing the Startup Configuration File and Rebooting is not the same as Rebooting to Factory
NOTE
Defaults. Rebooting to Factory Defaults is more intrusive.
Health
The Health page monitors the fan status on all devices with fans. Depending on the model, there are one or
more fans on a device. Some models have no fans at all.
Some devices have a temperature sensor to protect its hardware from overheating. In this case, the
following actions are performed by the device if it overheats and during the cool down period after
overheating:
Event
At least one temperature
sensor exceeds the
Warning threshold
At least one temperature
sensor exceeds the Critical
threshold
Cisco Small Business 200 Series Smart Switch Administration Guide
Action
The following are generated:
SYSLOG message
SNMP trap
The following are generated:
SYSLOG message
SNMP trap
The following actions are performed:
System LED is set to solid amber (if hardware
supports this).
Disable Ports — When the Critical
temperature has been exceeded for two
minutes, all ports will be shut down.
(On devices that support PoE) Disable the
PoE circuitry so that less power is consumed
and less heat is emitted.
6
64

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents