Download Print this page

DELTA DORE DRIVER 610 Installation Manual page 4

Pilot wire programmer
Hide thumbs Also See for DRIVER 610:

Advertisement

Programming
Turn the knob to
PROG
.
The default program is a Comfort period from 6:00 to
23:00.
1. Create your program
Programming starts on day 1 at midnight.
Press the
or
buttons to create different Economy
or Comfort periods.
Comfort period
Day
adjustment
Available on
Economy period
the DRIVER
adjustment
620 or 621
1st time slot
2. Confirm and copy the program
Press and hold the
OK
button for 3 seconds to confirm
the program you created and copy it to the next day.
3. Confirm the program
OK
Press the
button to confirm and continue on to the
next day to program it separately.
MINOR 500 option: set point settings
This mode is used to modify the Comfort and Economy set
points of each probe. Turn the knob to
.
Setting (5 to 30°C) of the Comfort
point (19°C by default) for the probe 1 of
zone 1.
Confirm and go to the next setting.
Setting (5 to 30°C) of the Economy
set point (16°C by default) for the probe 1
of zone 1.
Confirm and go to the set point settings
for the next probe.
Repeat the operations for each probe.
When the last probe is set, you can set the Frost
Protection set point for all the zones.
Setting (5 to 15°C) of the Frost Protection
set point (8°C by default) for all the zones.
Confirm the modification
To exit the mode, turn the knob to another mode.
Example: Comfort from 6:00 to 8:00 and from 17:00 to 23:00
00:00
6:00
8:00
17:00
Press
until you reach 6:00
Press
Press
until you reach 8:00
Press
Press
until you reach 17:00
Copy and confirm
Troubleshooting
The purpose of this section is to help you quickly solve
the most common problems that you may encounter
with your product during use.
set
If you're unsure, or if the problem persists or isn't in this
list, contact our customer service department.
Nothing is displayed on the room unit screen.
There is no power supply.
Check your circuit breaker.
i
The
symbol flashes.
A fault has been detected in the system.
Press the button to consult the fault or faults.
The unit displays: dEF and a number.
There is a fault on the unit or the installation.
Contact your installer or our customer service department.
The unit displays ---- instead of the temperature measured
by each MINOR 500 probe.
There is a problem on at least one of the probes.
Contact your installer or our customer service department .
The unit is in time setting mode.
There was a mains disruption that lasted more than 2 hours.
Set the time. All other settings have remained unchanged.
Check your program
23:00
00:00
Press the
button repeatedly to check the accuracy
of the Comfort and Economy periods you created.
Time slot
consulted
Program
profile
until you reach 23:00
Programming zone 2 (on the DRIVER 620 or 621)
The programming for zone 2 is available after pressing
(
OK
) of the day 7 of the zone 1.
Exiting the programming mode
Turn the knob to another mode.
until you reach 00:00
COMMENTS : Depending on the configuration made
during installation, programming can be weekly or
daily. Likewise, this programming may be done in
increments of one hour, 30 minutes, or 15 minutes. To
change these settings, refer to the "installation guide",
or contact our customer service department or your
installer.
or confirm
When setting the time, there is no option to set the day.
You are in daily programming.
To switch to weekly programming, refer to the installation
guide or contact your installer or our customer service depart-
ment.
The temperature displayed does not match the tempera-
ture measured in the room (thermometer).
Refer to the installation guide or contact your installer or our
customer service department.
The unit displays HEAT
Your underfloor heating or radiant ceiling heating system is in
"gradual heating" mode.
If you want to know the number of days remaining, press the
button.
The heating elements are in Frost Protection mode
You are in programming mode, the absence mode or time
setting mode.
Turn the knob to select another mode.
Pb ---- is displayed on the screen.
Problem with the connection of a heating element.
Contact your installer or our customer service department.
Verification of the
different
or
periods
i

Advertisement

loading

This manual is also suitable for:

Driver 620