Pilot wire programmer
Hide thumbs Also See for DRIVER 610:

Advertisement

Configuration
To enter the configura-
tion menus:
- Turn the knob to
,
then press and hold
i
the
button for 5
seconds.
The unit will propose 2 configurations to choose
from:
Unit reference number (for example, DRIVER 620)
Basic configurations
Advanced configurations
Unit version
Configuration mode
After each menu has been configured, the unit returns
to the choice of menus.
If you want to exit configuration, turn the selector knob
to the right.
Return to the factory configuration
The factory settings may be restored for each of the
menus.
i
Turn the knob to
, then press and hold the
for 5 seconds.
Hold down the menu button
you want to reinitialize
for 5 seconds
(example here with menu 1).
Then press the OK button
to confirm the reset.
Repeat these steps for the other menus.
To exit the mode, turn the knob to another mode.
Basic configurations (menu 1)
1
Press button
.
5 sec.
To modify the various settings, press the + or - buttons,
then press the OK button to validate and go to the next
setting.
Weekly (by default)
Programming
Daily
type selection
pas d'1 heure (par défaut)
Choix du pas de
pas de 30 minutes
programmation
pas de 15 minutes
Technical characteristics
• 230 V, 50 Hz power supply, ±10%
• Consumption: 2 VA
• Class II insulation
button
• 1 or 2 pilot wires output 0.1A / 230V
• Clock backup in the event of a blackout:
2 hours (per capacitor)
• Dimensions: WxHxD = 80 x 103 x 16 mm
• Protection index: IP 30
• Installation in an environment with normal pollution
levels
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
Advanced configurations (menu 2)
2
Press button
.
To modify the various settings, press the + or - buttons,
then press the OK button to validate and go to the next
setting.
Program modification authorized
Modification
authorization
Program modification unauthorized
for the user
Summary table of configurations
Type of program
1-01
0 = weekly
1 = daily
No program
1-02
0 = 1 hour
1 = 30 minutes
2 = 15 minutes
Modification authorization
2-01
0 = Program modifiable
1 = Non modifiable program
Correction of the temperature measured
2-02
by -5°C to +5°C in increments of 0.1°C.
Correction possible from -5°C to + 5°C
in increments of 0.1°C.
Correcting
Press the + or – buttons to modify,
the temperature
and press the OK button to confirm.
measured.
If there is a difference between the actual temperature
(taken with a thermometer) and the temperature mea-
sured and displayed by the unit, function 2-02 can be
used to compensate for the difference by changing the
way the sensor takes measurements.
Example: If the temperature
displayed by the unit is
19°C and the temperature
measured is 20°C, add 1°C
to the display and confirm
by pressing OK.
Help
Nothing is displayed on the room unit screen.
There is no power supply.
Check the circuit breaker.
Pb — is displayed on the screen.
Problem with the connection on a Pilot Wire output.
Contact our technical department.
i
the
symbol flashes.
A fault is detected on the installation.
Press the button to view the fault(s).
The device displays: dEF and a number
There is a fault with the unit which requires a return to
our after-sales service.
Contact our technical department.