Download Print this page

User Guide - DELTA DORE DRIVER 610 Installation Manual

Pilot wire programmer
Hide thumbs Also See for DRIVER 610:

Advertisement

User guide

DRIVER
Pilot wire programmer
DRIVER 610 or 620 - 1 or 2 zones, projecting
DRIVER 611 or 621 - 1 or 2 zones, with modular unit
DRIVER
DELTA DORE
Bonnemain - 35270 COMBOURG - France
E-mail : deltadore@deltadore.com
Device complying with the requirements of the directives:
CEE 2004/108 (Electromagnetic compatibility)
and CEE 2006/95 (Low voltage safety)
Because of changes in standards and equipment, the characteristics
given in the text and the illustrations of this document are not binding
unless confirmed by our services.
Presentation
This unit is used to program the Comfort or Economy
mode of the heating for 1 zone (DRIVER 610 or 611) or
2 zones (DRIVER 620 or 621),
To control the heat emitters, the programmer uses the
Pilot Wire.
Heat emitters
Programmer
Pilot Wire orders
Pilot wire
Independent from the power supply of the heat emitter,
the Pilot Wire is used to send the Comfort
,
Economy , Frost Protection
or Shutdown
requested by the programmer.
The required temperature is set on the thermostat of
each heat emitter (convectors, panel heaters, under-
floor heating or radiant ceiling heating, towel warmer
radiators, storage heaters, etc.).
IMPORTANT: The heat emitter must be in automatic
mode (PROG, AUTO,
, etc. depending on model)
to receive orders from the programmer..
Description
This guide is common to the DRIVER 610, 611, 620 or
621.
DRIVER
Modification
buttons
Selector
knob position
Selector
knob
Shutdown mode
Time setting
Absence mode
Programming
Timer mode
Automatic mode
Continuous mode
Timer mode
This mode is used to select a mode for a given time and for
one zone only.
Turn the knob to
Choice of the zone proposed on the DRIVER
620 or 621 (the other zone follows the AUTO
mode)
Confirm
Selection of the Economy
or Comfort
mode
Confirm
Adjustment of the duration from 15 minutes to
72 hours (in increments of 15 minutes)
Confirmation and
start of the
countdown
Return to AUTO mode at
To cancel the current
the end of the countdown
timer mode, turn the knob.
Shutdown mode
This mode shuts down your heating system.
Turn the knob to
.
Room
temperature
Pilot Wire
Setting on the heat emitter
order
(mode)
Comfort
Comfort setting (thermostat knob)
example : 19°C
Economy
Economy setting (thermostat knob)
example : 16°C
or Comfort –X°C
(depending on heat emitter model)
Absence
Frost protection set to 7°C or 8°C
(depending on model)
Shutdown
Heating shutdown
orders
Automatic mode
Turn the knob to
AUTO
.
DRIVER 610 or 611 follows the programming.
Current day
Time
Current mode
Room
temperature
Display in automatic mode
DRIVER 620 or 621 follows the programming in both
zones.
Current mode in
Time
zones 1 and 2
Current day
Room
temperature
Display in automatic mode
Continuous mode
This mode allows you to choose a continuous mode for
each of the zone.
Turn the knob to
, then press the modification but-
ton of the relevant zone to select the Comfort
Economy
. mode.
DRIVER 610 or 611
Current mode
Room
temperature
DRIVER 620 or 621
Current mode in zones 1 and 2
Room
temperature
To exit this mode, turn the knob.
Information button
During the AUTO,
or
modes, press the
repeatedly to find out:
• if you have the MINOR 500 option,
the temperature measured by each of the probes
declared during the installation.
probe no.
temperature
measured
by the probe
Indication of a probe or
probes on the installation
• the program of the current day per zone,
Comfort periods
Options
The following options are only available on the DRI-
Room
VER 611 or 621.
temperature
TYPHONE 500
When associated with the DRIVER 611 or 621, the
TYPHONE 500 allows you to control your heating
19°C
remotely by telephone.
MINOR 500
Regulates an underfloor heating or radiant ceiling hea-
16°C
ting system. In combination with the DRIVER 611 or
621, this unit is used to control the set points and
determine the room temperature measured by each
7°C or 8°C
probe.
No heating
Warnings
• Carefully read these instructions prior to use.
• Do not attempt to repair the unit yourself; after-
sales service is available.
Override
In automatic mode, override is used to go from
Comfort to Economy mode (or conversely) until the
next program change.
Example: it is 15:30 and you would like to switch to
Comfort mode before the set time (17:00).
Override
00:00
6:00
8:00
Current day programming on zone 1
Press the override
Information button
button of zone 1.
Current override
on zone 1.
Override for zone 1
Override for zone 2
Information button
To cancel the current override,
press the button once more.
Absence mode
This mode lets you place your home under Frost Protection
if you need to leave for several days.
Turn the knob to
.
or
Modification
of the mode
Modification of the
mode in zone 1
Modification of the
mode in zone 2
To cancel the current absence mode, turn the knob.
Time setting
i
button
Turn the knob to
.
The days flash.
Press + or - to change the day, then press OK to
confirm and continue on to the next setting.
Days
(1 : Monday... 7 : Sunday)
Hours
Repeat the operations to set the hours and minutes.
To leave the "setting the time" mode, turn the knob.
NOTE : If the unit is configured for a daily program,
the days setting is not offered.
15:30
17:00
23:00
00:00
At 17:00, the program will
return to its usual program.
Adjustment of the number of days
(1 to 365)
Example: for a departure on 1 March
and a return on 10 March, program
9 days of absence.
Automatic operation will resume on
10 March at midnight.
Confirm and start the
calendar countdown.
Return to AUTO mode at
the end of the countdown
Minutes

Advertisement

loading

This manual is also suitable for:

Driver 620