E. Image Adjustment Basic Procedure - Canon PC400 Service Manual

Hide thumbs Also See for PC400:
Table of Contents

Advertisement

<Pre-Checks>
Clean the parts.
Scanning system, pick-up/feeding
system, and delivery assembly.
Is the
setting of the density
NO
correction switch at the
middle?
YES
Set the switch to the
middle.
Select non-AE, and set the density control dial/lever
to 5.5; then, make two to three copies of the Test
Chart (NB-3, NA-2, NA-3); see Note 1.
Check the following:
1. Density of gray scale No. 9; see Note 2.
2. Difference in density between front and rear; see
Note 3.
3. Density of gray scale No. 1; see Note 3.
4. Fogging in white area; see Note 3.
<Optimum Density Adjustment>
Is gray
YES
scale No. 9 barely noted?
(See Note 2.)
NO
Is the
problem corrected by
YES
the density correction
switch?
NO
Is
optimum
density obtained by
YES
adjusting the intensity of
light?
(See
NO
Check the following:
1. Cartridge.
2. Scanning lamp unit.
3. DC controller/DC power supply PCB
(see "Troubleshooting by Image
Fault").

E. Image Adjustment Basic Procedure

End.
End.
Notes:
1. If a mono color cartridge is used, set the
density control dial to 4.5.
2. If NB3 is used, refer to gray scale No. 10.
3. The machine is not equipped with an
adjustment function for each type of image
fault; see "Troubleshooting by Image Fault."
4. For instructions on how to adjust the
intensity of light, see p. 2-2.
1-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc420Pc430Fc200Fc220

Table of Contents