Download Print this page

Samsung SCL300 Service Manual page 60

8mm camcorder

Advertisement

2-11. Y-FM Deviation (Hi8)
: This adjustment sets the Y_FM modulation
level in recording. For adjustment, playback
the self-recorded signal and observe the
VIDEO OUT signal.
Note : It is a little difficult to adjust because you
can check the waveform in playback mode
even though the adjustment is performed
in VCR record mode.
So you have to do it carefully.
a. Preparations
TAPE
HI-8 TAPE FOR RECORDING
EQUIPMENT
DC POWER SUPPLY, OSCILLOSCOPE
OTHER
TEST POINT
CN605 PIN13
ADDRESS
1B
NAME
Y-FM DEVIATE (HI8)
b. Connect a power source.
c. Get into the VCR adjustment mode.
d. Press the ÒTITLE (MODE UP)/DATE/TIME
(MODE DOWN)Ó button of CAMCORDER so
as to select the address 1B.
e. Insert a Hi-8 Tape to the camcorder.
f. Press the START/STOP button on the Rear
board so as to set the camcorder to RECORD-
ING mode.
g. Connect the oscilloscope to the adressed Test
Point.
14
13
12
11
10
9
8
7
6
5
4
3
2
1
h. Record for enough time to check the waveform
when you playback where you recorded in step f).
* 1 minute may be enough to check the wave-
form in playback mode.
Samsung Electronics
14
AUDIO OUT R
13
VIDEO OUT
12
AUDIO OUT R
11
PB RF
10
AUDIO OUT L
9
HD SW
8
VCR UNREG
7
JIG CS
6
VCR UNREG
5
JIG SCK
4
SS GND
3
JIG SO
2
JIG DETECT
1
JIG SI
i. Make sure that the waveform is to be as below.
If OK, go to step l).
j. In case of the waveform level is bigger than
1Vp-p, press the Data Down button so as to set
to down the waveform level and if the wave-
form level smaller than 1Vp-p, press the Data
Up button so as to set to up the waveform level.
k. Repeat step w), i), j).
WHITE ( APPROX. 100% )
APPROX.
0.7V
APPROX.
0.3V
H
l. Be sure to press the ÒMENU/ENTER(CON-
FIRM)Ó button of CAMCORDER to memorize
setting.
m. Reset the power source so as to fix the new
data to the camcorderÕs EEPROM.
Alignment and Adjustment
1.0 0.02Vp-p
5-39

Advertisement