Page 3
National Fire ventilator. All Viking Range ventilator kits are designed Protection Association (NFPA), and the specifically for use with Viking Range hoods. Use of any American Society for Heating, Refrigeration and non-Viking Range ventilator kit will void the hood warranty.
Page 4
IMPORTANT– Please Read and Follow! W A R N I N G To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.) 1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner.
Dimensions & Specifications (VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”) Make sure the back wall *For best results, center the unit over of the custom hood canopy is flush with the the burners of the cooking product cutout so the ventilator system may be mounted (front to back;...
Installing Hood Canopy (Custom Hood Canopy Cutouts Custom Hood Canopy 1) Position ventilator system inside of the custom hood canopy Built-In Ventilator and center it front to back and left to right. System 2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.
Planning Information Proper installation of ducting is extremely 300 or 600 CFM important to ensure maximum performance from Roof Cap single blower any ventilation product. interior-power 7” round duct typical ductwork • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.
Installation (VWH/CVWH 12”H. Wall Hoods w/Standard Ventilator) Check damper for unrestricted movement, adjust if Attach transition to damper. Seal with aluminum tape. necessary. W A R N I N G To reduce the risk of fire, electric shock, or injury to persons, observe the following: •...
Page 29
CAUTION: If not using a duct cover, using screws CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting anchors, if necessary.
Duct Cover Option (VWH/CVWH 12”H. Wall Hoods w/Standard Ventilator) Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) Remove damper and discard with transition. Turn recirculating unit upside down.
Page 31
Installation (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) Attach with screws and lock washers provided. Attach with screws. W A R N I N G To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer.
Page 32
Installation (con’t) (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) Bare or Green Green Black White Black White Connect black to black, white to white, and the Replace electrical box cover. Make connection to green/bare wire under the green screw. breaker box. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. To install ventillation kit refer to ventillation kit installation instructions.
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) Measure distance from ceiling to canopy. Tape to avoid scratching. Place duct cover top inside duct cover base and lower until Slide the duct cover in place and fasten from inside desired height is found. Mark height. Use the retaining canopy using the sheet metal screws provided.
Installation (VCIH/CVCIH Island Hoods) Check framing where cutout will be. Cut appropriate size hole in ceiling. Either 7” or 10” NOTE: 200 lb. limit . depending on your specific unit and ventillator kit. Mounting options: Using duct cover with ceiling mounting bracket.
Page 37
Installation (VCIH/CVCIH Island Hoods) Run duct work down to bottom edge of duct Attach canopy to duct cover/soffit. Seal top of hood to cover/soffit and secure in place. Make sure the duct duct with aluminum tape. does not stick down past the cover. Slide filter front over front lip.
• Name of dealer from whom purchased Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to:...
Page 40
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com in the US brigade.ca in Canada F21287B EN (113014)