Falcon E3860B Operating, Installation And Servicing Instructions

Advertisement

E3860B & E3865B
E3860F & E3865F
DOMINATOR
INSTALLATION and
SERVICING INSTRUCTIONS
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation. Particular attention MUST be paid to:
BS7671 IEE Wiring Regulations
Electricity at Work Regulations
Health and Safety at Work Act
Fire Precautions Act
This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC
Directives for the voltages stated on the data plate.
WARNING
THIS APPLIANCE MUST BE EARTHED.
:
On completion of the installation, these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a maintenance
contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out
adjustments and repairs. A quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement
parts in a safe manner, via a licensed waste handler.
Units are designed to be dismantled easily and recycling of all
material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000
PLUS
Fax: 01438 369 900
Fryers
T100981 Ref. 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E3860B and is the answer not in the manual?

Questions and answers

Summary of Contents for Falcon E3860B

  • Page 1 E3860B & E3865B E3860F & E3865F PLUS DOMINATOR Fryers INSTALLATION and SERVICING INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to:...
  • Page 2 IMPORTANT INFORMATION Warranty Policy Shortlist Warranty does not cover:- • Correcting faults caused by incorrect installation of a product. • Where an engineer cannot gain access to a site or a product. • Repeat commission visits. • Replacement of any parts where damage has been caused by misuse. •...
  • Page 3: Section 1 - Installation

    Weight Model (mm) (mm) (mm) (kg) E3860B Fryer E3860F Fryer E3865B Fryer E3865F Fryer 1.2 SITING Before connecting appliance to electricity supply, it must be correctly positioned and leveled. The lowest point of the oil bucket carriage must be at least 10mm from the floor.
  • Page 4: Section 2 - Assembly And Commissioning

    Fill pan(s) with oil to minimum mark on element guard (i.e. approximately 20 litres for E3830B/F model and 40 litres for E3860B/F & E3865B/F models) and switch on at isolator switch. Turn thermostat to maximum setting and check that it operates at the correct temperature of 190°C.
  • Page 5: Section 3 - Servicing And Maintenance

    SECTION 3 - SERVICING and MAINTENANCE BEFORE ATTEMPTING ANY MAINTENANCE TASK, ISOLATE THE APPLIANCE AT THE MAIN SUPPLY. TAKE STEPS TO ENSURE THAT IT MAY NOT BE INADVERTENTLY SWITCHED ON. 3.1 ELECTRICAL CONTROL GEAR The mains terminals are located at rear of unit. The control thermostat(s) and neon lamps are mounted on the facia panel, which is secured by four fixings.
  • Page 6: Section 4 - Spares

    3.7 FILTRATION PUMP Remove the rear access panel(s). Disconnect the filtration flexi hose from the pump. Disconnect the electrical coupling plug located inside the electrical box. Remove the nut from the pump capacitor. Remove pump mounting bolts and lift pump clear taking the capacitor with it. Replace in reverse order. Note: Check for oil leaks before replacing any panels.
  • Page 7 E3865F WIRING DIAGRAM...
  • Page 8 E3865F CIRCUIT DIAGRAM...
  • Page 9 E3860F WIRING DIAGRAM...
  • Page 10 E3860F CIRCUIT DIAGRAM...
  • Page 11 E3865B WIRING DIAGRAM...
  • Page 12 E3865B CIRCUIT DIAGRAM...
  • Page 13 E3860B WIRING DIAGRAM...
  • Page 14 E3860B CIRCUIT DIAGRAM...

This manual is also suitable for:

E3865bE3860fE3865f

Table of Contents