Model BX42E
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS,
RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
VGZ-005 / 20120202.0
(save this manual for future reference)
Vogelzang International Corp.
Owners Manual
NOTE: THIS STOVE IS
NOT A UL LISTED STOVE.
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
Page 1
BX42E-SN /

Advertisement

Table of Contents
loading

Summary of Contents for Vogelzang International DELUXE BOXWOOD BX42E

  • Page 1 SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...
  • Page 2: Safety Precautions

    SAFETY INSTRUCTIONS Read All Instructions carefully. Residential Type and Building Heating Appliance 1. The installation of this stove must comply with your Chimney. Use a 6˝/152mm diameter chimney, local building code rulings. Please observe the that is high enough to give a good draft. (See clearances to combustibles (see reference figures specifics in Chimney Connections instructions).
  • Page 3 30. A WOOD-BURNING STOVE MUST NEVER BE INSTALLED IN A HALLWAY OR NEAR A STAIR- CASE, as it may block egress in the event of a fire. 31. DO NOT INSTALL IN A SLEEPING ROOM. Page 3 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Safety Precautions ..................2 – 3 Tools and Materials Required for Installation ........... 5 Assembly Instructions ..................5 Locating the Stove ..................... 6 Floor Protector, Minimum Clearances ..........6–7 Connector Pipe Installation ................8 Chimney Connections/Draft ................ 9 –11 Operating Instructions House Fire Hazards, Operating Precautions, Warnings ......
  • Page 5: Tools And Materials Required For Installation

    ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS REQUIRED MATERIALS REQUIRED (NOTE: The following items are NOT included with your stove) Safety Glasses 1/8”...
  • Page 6: Locating The Stove

    ASSEMBLY INSTRUCTIONS continued… LOCATING STOVE Proper clearances must be maintained for ad- CAUTION: (FIRE HAZARD) CARPETING AND equate air circulation and protection from radi- OTHER COMBUSTIBLE MATERIAL MUST NOT a n t h e a t . A d e q u a t e v e n t i l a t i o n m u s t b e COVER THE FLOOR PROTECTOR.
  • Page 7 Pipe Connector to Backwall ... 38 inches Pipe Connector to Ceiling ..18 inches CAUTION: KEEP FURNISHINGS AND OTHER Figure 8 – Top View COMBUSTIBLE MATERIALS AWAY FORM THE Minimum Corner Clearances from STOVE. Combustible Surfaces Page 7 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...
  • Page 8: Connector Pipe Installation

    CONNECTOR PIPE INSTALLATION 2. Horizontal pipe runs must slope upwards NOTE: CONNECTOR PIPE IS NOT INCLUDED. towards the chimney at least 1/4˝(6.4mm) per foot TO PURCHASE, VISIT YOUR LOCAL HARD- of horizontal run. WARE, HOME, OR BUILDING CENTER. 3. You must have at least 18˝/457mm of clearance SEE “LOCATING STOVE”...
  • Page 9: Chimney Connections/Draft

    5. C o n t a c t y o u r l o c a l b u i l d i n g a u t h o r i t y for approved methods of installation and any necessary permits and/or inspections. Figure 11 - Chimney Construction Through Attic Space Page 9 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...
  • Page 10 CHIMNEY CONNECTIONS continued … MANUFACTURED CHIMNEY Use only 6” diameter listed chimney UL 103 HT. Chimney made to this listing is High Temperature rated REFER TO CHIMNEY AND CHIMNEY CONNEC- to 2100 degrees Fahrenheit. Use chimney from only one TOR MAKER’S INSTRUCTIONS FOR INSTALLATION manufacturer.
  • Page 11 Positioning the center of the stove pipe entry into the chimney 24” below the ceiling should insure proper clearance for a 6” stovepipe. Figure 14 - Fireplace Conversion Page 11 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...
  • Page 12: Operating Instructions

    OPERATING INSTRUCTIONS This stove is designed to burn CAUTION: HOUSE FIRE HAZARDS WOOD FUEL ONLY. Hardwood, 20” to 24” should be air dried (sea- TOR, UNDERNEATH STOVEPIPE, OR ANY- soned), for a minimum of 6 months. Logs grater than WHERE WITHIN MINIMUM CLEARANCES FROM 6˝...
  • Page 13: Adding Fuel

    RECOMMENDED MATERIALS SUCH AS a large quantity of coarse salt, baking soda, or cool TRASH OR FLAMMABLE LIQUIDS MAY CAUSE ashes on top of the fire. OVER FIRING. continued on next page Page 13 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...
  • Page 14: Stove Joints

    MAINTENANCE & SERVICE continued … Preventing Creosote Buildup 2. If the chimney temperature is too cool, water will condense in the chimney and run back into 1. Creosote will inevitably form in your chimney and the stove. Creosote formation will be rapid and may connector pipe.
  • Page 15: Parts - Deluxe Boxwood

    S-Hook (used to hang lid lifter) ....1 42-17 Spin Draft ............ 1 42-18 Door Latch ........... 1 42-19 Gasket, Door (1/4” dia. fiberglass) ....1 HP-42 Hardware Pack ........... 1 Page 15 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...
  • Page 16: Floor Protector Calculations

    FLOOR PROTECTOR MATERIAL CALCULATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions on page 3, “Locating Stove” step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
  • Page 17: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 17 VGZ-005 / 20120202.0 Vogelzang International Corp. BX42E-SN /...