8.4 Operation Modes and Functions

8.4.1 Fan mode
1) Outdoor fan and compressor stop.
(
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates same as in cooling mode.
(5) Auto fan:
For MS11M-09HRFN1-MW0W, MS11M-12HRFN1-MV0W, MS11M-18HRFN1-MU0W models:
T 1 - 2 4
For MS11M-24HRFN1-MT0W model:
8.4.2 Cooling Mode
8.4.2.1 Compressor running rules
The maximum operation frequency of compressor after starting submits to following rule.
6 . 0
a
5 . 0
b
4 . 0
c
2 . 5
d
1 . 0
e
27.5
27
25.5
25
H
( H - L ) * 0 . 7 5 + L
( H - L ) * 0 . 5 + L
( H - L ) * 0 . 2 5 + L
L
High
Medium
Low