Testing the Sensors

1. Select Sensor Tests from the Printer Diagnostics window.
For the On-Demand sensor, the range is between 0 and 5.0. When you hold a label over the
sensor, the values change on the display. When the sensor is blocked by a label, the value is
at the high end of the range. When the sensor is not blocked, the value is zero or close to zero.
On-Demand
Sensor
2. You see the values for battery voltage, black mark
voltage, on-demand voltage, and printhead temperature.
The battery voltage range is between 7.0 and 8.4 volts.
The printer does not print if the voltage is below 7.0.
3. Open the cover to test the sensors.
For the Black Mark sensor, hold a black mark against the
sensor as shown. When you place the black mark on the
sensor, the values change on the display. If white is over
the sensor, the values shown for the sensor are higher.
The range is between 0 and 5.0.
Black Mark Sensor
Place black mark o ver
sensor.
Using Printer Diagnostics 4-7