Bosch DS484Q Installation Instructions Manual page 11

Quad beam photoelectric detectors
Table of Contents

Advertisement

.
4.1.2
Transmitter Setup
Figure 15: Transmitter Setup Switches
130
160
260
320
100
200
OUTDOOR
60
INDOOR
120
BEAM POWER CONTROL (m)
SWITCH
OFF ↔ ON
No ITEM OFF ON
1 Group
A
B
2
SEE CHART
3
BELOW
4 NULL
-
-
SW2 - 3 : CHANNEL
M
1
2
3
SW2
OFF
OFF
ON
ON
SW3
OFF
ON
OFF
ON
MODEL:DS486Q
1 - Beam Power Control rotary switch
2 - DIP Switches 1, 2, and 3
Turn the Beam Power Control rotary switch to the
volume setting for the appropriate detection range.
Refer to Figure 15, Table 5 and Table 6.
Table 5:
Settings for Outdoor Beam Power
Control
DS484Q
Volume
Range
Setting
m (ft)
40
0 to 40
(0 to 131)
60
40 to 60
(131 to 197)
80
60 to 80
(197 to 263)
100
80 to 100
(263 to 328)
110
100 to 110
(328 to 361)
120
110 to 120
(361 to 394)
Bosch Security Systems, Inc. | 7/05 | 4998138530F
DS484Q/DS486Q | Installation Instructions | 4.0
POWER
1
180
360
200
400
2
DS486Q
Volume
Range
Setting
m (ft)
60
0 to 60
(0 to 197)
100
60 to 100
(197 to 328)
130
100 to 130
(328 to 427)
160
130 to 160
(427 to 525)
180
160 to 180
(525 to 591)
200
180 to 200
(591 to 656)
Table 6:
Settings for Indoor Beam Power
Control
DS484Q
Volume
Range
Setting
m (ft)
80
0 to 80
(0 to 263)
120
40 to 120
(263 to 394)
160
120 to 160
(394 to 525)
200
160 to 200
(525 to 656)
220
200 to 220
(656 to 722)
240
220 to 240
(722 to 787)
4.1.3
Beam Group and Channel Setup
When installing only one transmitter and
one receiver (a set), beam group and
channel selection is not required. Leave the
switches on the transmitter and receiver in
the original (OFF) positions. Refer to
Figure 17 on page 12.
The transmitter and the receiver have eight selectable
beams. The beams are divided into two groups
(Group A and Group B) of four beams each. The
beams are referred to as channels (Channels M, 1, 2,
and 3). Refer to Figure 16.
Figure 16: Beam Group and Channel
Organization
BEAM
GROUP A
GROUP B
Channels 1, 2 or 3 can emit beams only when
Channel M in the same group provides those channels
with synchronized (synchro) wiring. Refer to Section
4.1.4 Synchronized Wiring on page 12. When installing
two or more sets in the same group, set only the first
set to Channel M. Set the remaining sets to Channel 1,
2, or 3.
Setup and Alignment
DS486Q
Volume
Range
Setting
m (ft)
120
0 to 120
(0 to 394)
200
120 to 200
(394 to 656)
260
200 to 260
(656 to 853)
320
260 to 320
(853 to 1050)
360
320 to 360
(1050 to 1181)
400
360 to 400
(1181 to 1312)
CHANNEL M
CHANNEL 1
CHANNEL 2
CHANNEL 3
CHANNEL M
CHANNEL 1
CHANNEL 2
CHANNEL 3
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds486q

Table of Contents