EPLACING THE
ICK
OLLERS
Install the new Separation
Roller onto the shaft. Make
sure to align the slot in the
roller collar with the screw in
the shaft.
Install the new Pick Roller
onto the shaft.
Note:
Make sure that the belt is facing up and the wide plastic foot slides
into the groove in the bottom of the roller compartment.
Wide Plastic Foot
Make sure to align the slot in the roller collar with the screw in the
shaft.
Close the Pick Roller Cover.
Close the ADF.
Refer to "Resetting The Consumables Counters" later in this document
to reset the Pick Roller Counter.
fi-6670(A) & fi-6770(A) C
(
.)
CONT
Make sure belt is facing up.
Groove
R
ONSUMABLE
EPLACEMENT AND
C
I
LEANING
NSTRUCTIONS