Table 10
POST error messages
Error Code
608h
609h
612h
611h
615h
616h
617h
618h
Error message
Fan Solution Not Sufficient!
Critical Failure Detected - System
Shutting Down in xx seconds!
Temperature Violation Detected!
Waiting 5 minutes for system to
cool.
Press ESC Key to resume booting
without waiting for the system to
cool.
Warning: Pressing ESC is NOT
recommended as system may
shutdown unexpectedly.
Recheck Temperature in xxx
seconds!
Power Supply Failure or Power
Supply Unplugged
System Event Log full
System Fan 1 missing!
The cooling solution is not
redundant due to a detected fan
failure.
System Fan 2 missing!
The cooling solution is not
redundant due to a detected fan
failure.
System Fan 3 missing!
The cooling solution is not
redundant due to a detected fan
failure.
System Fan 4 missing!
The cooling solution is not
redundant due to a detected fan
failure.
Description/corrective action
If one or more fans are missing, this
message will appear with 'system
fan x missing' together.
If system detects one or more
temperature sensors over heating,
this message will appear.
When two power supplies are
installed, if one of the power cable
is not connected or one of the
power is failed, this will appear.
If system cannot store any more
event log, this will appear at post.
If only system fan1 is not installed or
failed, system will announce this
message and press F1 continue to
boot
If only system fan2 is not installed or
failed, system will announce this
message and press F1 continue to
boot
If only system fan3 is not installed or
failed, system will announce this
message and press F1 continue to
boot
If only system fan4 is not installed or
failed, system will announce this
message and press F1 continue to
boot