HP ProLiant SL2x170z G6 Server Maintenance And Service Manual page 74

Hide thumbs Also See for ProLiant SL2x170z G6 Server:
Table of Contents

Advertisement

Table 10
POST error messages
Error Code
012h
048h
04Ch
05Dh
05Eh
110h
613h
604h
605h
606h
607h
Error message
CMOS Date/Time Not Set
Password check failed
Keyboard/Interface Error
S.M.A.R.T. Status BAD, Backup and
Replace
Password check failed
Un-correctable DRAM ECC Error
detected at
cpuXX/DIMM0X(cpu01/DIMM08)
Power supplies mismatch, replace
slot#2 with identical Power supply
Press F1 to continue booting with
one power supply
System Fan 1 Missing
System Fan 2 Missing
System Fan 3 Missing
System Fan 4 Missing
Description/corrective action
The CMOS Date and/or Time
are invalid. This error can be
resolved by readjusting the
system time in the Setup Utility.
Password is incorrect after retried a
few times. Users might need to reset
the password.
Keyboard controller failed test. This
may indicate a problem with system
hardware.
Hard Disk S.M.A.R.T feature test
fail, indicate a problem with hard
disk
If user inputs incorrect password
more than three times, then display
this error information and continue
to boot.
Detect multi-bit error in the DIMM
prompt, press F1 continue to boot
When two power supplies are
installed, if their vendor are
different, this will appear and
system will halt.
If system fan1 is not installed or
failed, system will announce this
message and system will shutdown
in minutes.
If system fan2 is not installed or
failed, system will announce this
message and system will shutdown
in minutes.
If system fan3 is not installed or
failed, system will announce this
message and system will shutdown
in minutes.
If system fan4 is not installed or
failed, system will announce this
message and system will shutdown
in minutes.
Diagnostic tools and Setup Utilities 74